MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1136/jcp.35.4.434

Медицинская библиотека · Journal of clinical pathology · 1982

Polyvalent heat-killed antigen for the diagnosis of infection with Legionella pneumophila.

Fallon R J, Abraham W H

СтатьяПеревод в очереди

Аннотация

A polyvalent antigen composed of heat-killed agar-grown Legionella pneumophila serogroups 1-4 suspended in a suspension of yolk-sac from embryonated hens' eggs has been examined for use in the indirect fluorescent antibody test for Legionella infection. The serological response detected by monovalent antigen correlated well with that detected by polyvalent antigen. The use of polyvalent antigen forms a useful screening test for the detection of antibody to L pneumophila, but positive results must be confirmed by test using monovalent antigen.

Для цитирования: Fallon R J, Abraham W H. Polyvalent heat-killed antigen for the diagnosis of infection with Legionella pneumophila.. Journal of clinical pathology. 1982. DOI: 10.1136/jcp.35.4.434.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.