MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1017/s1047951123000380

Медицинская библиотека · Cardiology in the young · 2023

Extra-cardiac and complex Fontan baffle fenestration using radio frequency current via surgical electrocautery.

Khan Asra, Qureshi Athar M, Bansal Manish, Stapleton Gary, Webb Melissa K, Lam Wilson, Eilers Lindsay, Singh Harinder R, Gowda Srinath T

СтатьяПеревод в очереди

Аннотация

BACKGROUND

Fontan baffle punctures and creation of Fontan fenestration for cardiac catheterisation procedures remain challenging especially due to the heavy calcification of prosthetic material and complex anatomy.

OBJECTIVES

We sought to evaluate our experience using radiofrequency current via surgical electrocautery needle for Fontan baffle puncture to facilitate diagnostic, electrophysiology, and interventional procedures.

METHODS

A retrospective chart review of all Fontan patients (pts) who underwent Fontan baffle puncture using radiofrequency energy via surgical electrocautery from three centres were performed from January 2011 to July 2021.

RESULTS

A total of 19 pts underwent 22 successful Fontan baffle puncture. The median age and weight were 17 (3-36 years) and 55 (14-88) kg, respectively. The procedural indications for Fontan fenestration creation included: diagnostic study (n = 1), atrial septostomy and stenting (n = 1), electrophysiology study and ablation procedures (n = 8), Fontan baffle stenting for Fontan failure including protein-losing enteropathy (n = 7), and occlusion of veno-venous collaterals (n = 2) for cyanosis. The type of Fontan baffles included: extra-cardiac conduits (n = 12), lateral tunnel (n = 5), classic atrio-pulmonary connection (n = 1), and intra-cardiac baffle (n = 1). A Fontan baffle puncture was initially attempted using traditional method in 6 pts and Baylis radiofrequency trans-septal system in 2 pts unsuccessfully. In all pts, Fontan baffle puncture using radiofrequency energy via electrocautery needle was successful. The radiofrequency energy utilised was (10-50 W) and required 1-5 attempts for 2-5 seconds. There were no vascular or neurological complications.

CONCLUSIONS

Radiofrequency current delivery using surgical electrocautery facilitates Fontan baffle puncture in patients with complex and calcified Fontan baffles for diagnostic, interventional, and electrophysiology procedures.

Для цитирования: Khan Asra, Qureshi Athar M, Bansal Manish, Stapleton Gary, Webb Melissa K, Lam Wilson, Eilers Lindsay, Singh Harinder R, Gowda Srinath T. Extra-cardiac and complex Fontan baffle fenestration using radio frequency current via surgical electrocautery.. Cardiology in the young. 2023. DOI: 10.1017/s1047951123000380.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.