m+Medelevator.RU
← Поиск публикаций
The Journal of bone and joint surgery. American volume · 2014

Reconstruction of the coronoid process using the tip of the ipsilateral olecranon.

Оценочное исследованиеСтатьяПоддержка исследования: вне правительства СШАНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Alolabi Bashar, Gray Alia, Ferreira Louis M, Johnson James A, Athwal George S, King Graham J W

Аннотация

BACKGROUND: Autograft reconstruction of the coronoid using the tip of the olecranon has been described as a treatment option for comminuted coronoid fractures or coronoid nonunions that are not repairable. The purpose of this in vitro biomechanical study of the coronoid-deficient elbow was to determine whether coronoid reconstruction using the tip of the ipsilateral olecranon would restore elbow kinematics.

METHODS: An elbow motion simulator was used to perform active and passive extension of six cadaveric arms in the horizontal, valgus, varus, and vertical orientations. Elbow kinematics were quantified with use of the screw displacement axis of the ulna with respect to the humerus. Testing was performed with an intact coronoid, a 40% coronoid deficiency, and a coronoid reconstruction using the tip of the ipsilateral olecranon.

RESULTS: Creation of a 40% coronoid deficiency resulted in significant changes (range, 3.6° to 10.9°) in the angular deviations of the screw displacement axis relative to the intact state during simulated active and passive extension in the varus orientation with the forearm in pronation and in supination (p < 0.05). Reconstruction of the coronoid using the ipsilateral olecranon tip restored the angular deviations to those in the intact state (p > 0.05) with the arm in all orientations except valgus, in which there was a small but significant difference (0.4° ± 0.2°, p = 0.04) during passive motion with forearm supination.

CONCLUSIONS: Reconstruction of the coronoid using the tip of the ipsilateral olecranon was an effective method for restoring normal kinematics over a range of elbow motion from 20° to 120° in a cadaveric model of an elbow with a 40% coronoid deficiency. This reconstruction technique may prove beneficial for patients with elbow instability due to coronoid deficiency.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты