MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1111/os.12859

Медицинская библиотека · Orthopaedic surgery · 2020

Forearm Interosseous Membrane Maintains the Stability of Proximal Radioulnar Joint.

Zhang Ning, Fang Jia-Hu

СтатьяПеревод в очереди

Аннотация

OBJECTIVE

To evaluate the effect of the proximal and central bundles of the interosseous membrane on the stability of proximal radioulnar joint.

METHODS

Twenty fresh samples of human forearm provided by the anatomy room of the Department of Human Anatomy of Nanjing Medical University were included in this study. They were used to explore the effect of proximal interosseous membrane bundle on the stability of proximal radioulnar joint. The proximal bundle was reconstructed along the original attachment point. The reconstructions of central bundle were divided into the reconstruction of original attachment point on radius-midpoint of the ulnar original attachment point (reconstruction A) and original attachment point reconstruction (reconstruction B). The loads of the proximal radioulnar joint in different positions were measured. The load of the proximal radioulnar joint was analyzed in neutral, pronation, and supination positions.

RESULTS

After resection of proximal and central fascicles, the loads of proximal radioulnar joint in neutral, pronation, and supination positions were significantly lower than those before resection (P < 0.05). After reconstruction, the loads of proximal radioulnar joint in neutral and supination positions were higher than those after resection (P < 0.05). After reconstruction, the loads of proximal radioulnar joint in neutral and supination positions were higher than those after resection (P < 0.05), and that after reconstruction B in pronation position was higher than that after resection (P < 0.05), while there was no significant difference between reconstruction A and after resection (P > 0.05). In supination position, the load of reconstruction B was higher than that of reconstruction A (P < 0.05). After reconstruction of the proximal and central bundles, the proximal radioulnar joint could not reached the same load as it could before resection (P < 0.05).

CONCLUSION

The stability of proximal radioulnar joint is affected by central bundle and proximal bundle. Reconstruction can increase the stability of proximal radioulnar joint.

Для цитирования: Zhang Ning, Fang Jia-Hu. Forearm Interosseous Membrane Maintains the Stability of Proximal Radioulnar Joint.. Orthopaedic surgery. 2020. DOI: 10.1111/os.12859.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.