Медицинская библиотека · The New England journal of medicine · 2025

Lorundrostat Efficacy and Safety in Patients with Uncontrolled Hypertension.

Laffin Luke J, Kopjar Branko, Melgaard Carrie, Wolski Kathy, Ibbitson Jessica, Bhikam Shivani, Weir Matthew R, Ofili Elizabeth O, Mehra Reena, Luther James M, Cohen Debbie L, Sarraju Ashish, Wilkinson Michael J, Flack John M, Rodman David, Nissen Steven E, Advance-HTN Investigators

Клиническое исследование II фазыСтатьяМногоцентровое исследованиеРандомизированное исследованиеПеревод в очереди

Аннотация

BACKGROUND

Aldosterone dysregulation contributes to hypertension. Lorundrostat is an aldosterone synthase inhibitor, but data on its efficacy and safety in patients with hypertension are limited.

METHODS

In this multicenter, double-blind, randomized, placebo-controlled trial, we assigned participants who were receiving two to five antihypertensive medications and had a blood-pressure measurement of 140/90 mm Hg or higher obtained during an office visit to undergo a standardized antihypertensive regimen for 3 weeks. Subsequently, participants with an average 24-hour ambulatory blood pressure of 130/80 mm Hg or higher were assigned to receive placebo, lorundrostat at a stable dose of 50 mg daily (the stable-dose group), or lorundrostat at a starting dose of 50 mg daily, with an increase to 100 mg daily if systolic blood pressure was 130 mm Hg or higher after 4 weeks (the dose-adjustment group). The primary end point was the change in 24-hour average systolic blood pressure from baseline to week 12, assessed as the least-squares mean difference from placebo (the placebo-adjusted change) in each lorundrostat group. A key secondary end point was the change in 24-hour average systolic blood pressure from baseline to week 4, assessed as the placebo-adjusted change in the combined lorundrostat groups.

RESULTS

A total of 285 participants underwent randomization; 94 were assigned to the stable-dose group, 96 to the dose-adjustment group, and 95 to the placebo group. The mean age was 60 years, and 150 participants (53%) were Black. After 12 weeks, the least-squares mean change in 24-hour average systolic blood pressure was -15.4 mm Hg in the stable-dose group, -13.9 mm Hg in the dose-adjustment group, and -7.4 mm Hg in the placebo group. The placebo-adjusted change in blood pressure was -7.9 mm Hg (97.5% confidence interval [CI], -13.3 to -2.6) in the stable-dose group and -6.5 mm Hg (97.5% CI, -11.8 to -1.2) in the dose-adjustment group. The placebo-adjusted change in 24-hour average systolic blood pressure from baseline to week 4 in the combined lorundrostat groups was -5.3 mm Hg (95% CI, -8.4 to -2.3). A potassium level above 6.0 mmol per liter occurred in 5 participants (5%) in the stable-dose group, 7 participants (7%) in the dose-adjustment group, and no participants in the placebo group.

CONCLUSIONS

Lorundrostat was associated with greater reductions in 24-hour average blood pressure than placebo in participants with uncontrolled and treatment-resistant hypertension. (Funded by Mineralys Therapeutics; Advance-HTN ClinicalTrials.gov number, NCT05769608.).

Для цитирования: Laffin Luke J, Kopjar Branko, Melgaard Carrie, Wolski Kathy, Ibbitson Jessica, Bhikam Shivani, Weir Matthew R, Ofili Elizabeth O, Mehra Reena, Luther James M, Cohen Debbie L, Sarraju Ashish, Wilkinson Michael J, Flack John M, Rodman David, Nissen Steven E, Advance-HTN Investigators. Lorundrostat Efficacy and Safety in Patients with Uncontrolled Hypertension.. The New England journal of medicine. 2025. DOI: 10.1056/nejmoa2501440.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.