MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1093/ehjimp/qyaf160

Медицинская библиотека · European heart journal. Imaging methods and practice · 2025

From simple measurement to a complex form: right ventricular volumetry using 2D-echocardiography-a retrospective cohort study.

Seiler Raphael, Günther Felix, Hinke Alexandra, Groß Florian, Lerach Teresa, Brüning Jan, Dragendorf Robert, Berger Felix, Kühne Titus, Bobenko Alexander, Ovrutskiy Stanislav

СтатьяПеревод в очереди

Аннотация

AIMS: Assessment of right ventricular volume is crucial for monitoring patients with congenital heart defects. However, due to the right ventricle's complex geometry, 2D echocardiography is challenging and MRI is commonly used to evaluate right ventricular volume. However, MRI has several limitations: it lacks bedside imaging, is time-consuming, and often requires sedation in patients with congenital heart defects. Therefore, we aimed to develop a reliable and simple method for calculating right ventricular volume using 2D echocardiography.

METHODS AND

RESULTS

Standard apical 4-chamber and parasternal short-axis views were obtained using 2D echocardiography in 40 congenital heart defects patients. Right ventricular volumes were calculated using an ellipsoidal shell model, a truncated cone model and a novel approach based on a cone model: V RV = 2 3 ( A SAX + 1 8 π d TV 2 ) A 4 CH d TV . The results were compared with right ventricular volumes obtained via MRI. The proposed cone-based model demonstrated excellent correlation to right ventricular volumes obtained by MRI (systolic: ICC = 0.98 (95% CI 0.95-0.99)/diastolic: ICC = 0.96 (95% CI 0.92-0.98)). The mean difference from MRI-measured systolic volume was 0.1 mL (SD ± 13.3) and from diastolic volume 5.2 mL (SD ± 28.2). Based on the root mean square error (RMSE) our cone model (RMSE 13.2 mL/28.4 mL systolic/diastolic) demonstrates significantly better predictive accuracy than the traditional ellipsoidal shell model (RMSE 20.8 mL/52.6 mL systolic/diastolic) and the truncated cone model (RMSE 25.1 mL/42.3 mL systolic/diastolic).

CONCLUSION

Our method shows excellent alignment with MRI data. It offers an accurate and rapid method for bedside assessment of right ventricular volume with 2D echocardiography, enhancing prompt and precise clinical decision-making.

Для цитирования: Seiler Raphael, Günther Felix, Hinke Alexandra, Groß Florian, Lerach Teresa, Brüning Jan, Dragendorf Robert, Berger Felix, Kühne Titus, Bobenko Alexander, Ovrutskiy Stanislav. From simple measurement to a complex form: right ventricular volumetry using 2D-echocardiography-a retrospective cohort study.. European heart journal. Imaging methods and practice. 2025. DOI: 10.1093/ehjimp/qyaf160.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.