MedElevator Войти в исследования
← Поиск публикаций

DOI 10.3390/s24020682

Медицинская библиотека · Sensors (Basel, Switzerland) · 2024

Classification of Adventitious Sounds Combining Cochleogram and Vision Transformers.

Mang Loredana Daria, González Martínez Francisco David, Martinez Muñoz Damian, García Galán Sebastián, Cortina Raquel

СтатьяПеревод в очереди

Аннотация

Early identification of respiratory irregularities is critical for improving lung health and reducing global mortality rates. The analysis of respiratory sounds plays a significant role in characterizing the respiratory system's condition and identifying abnormalities. The main contribution of this study is to investigate the performance when the input data, represented by cochleogram, is used to feed the Vision Transformer (ViT) architecture, since this input-classifier combination is the first time it has been applied to adventitious sound classification to our knowledge. Although ViT has shown promising results in audio classification tasks by applying self-attention to spectrogram patches, we extend this approach by applying the cochleogram, which captures specific spectro-temporal features of adventitious sounds. The proposed methodology is evaluated on the ICBHI dataset. We compare the classification performance of ViT with other state-of-the-art CNN approaches using spectrogram, Mel frequency cepstral coefficients, constant-Q transform, and cochleogram as input data. Our results confirm the superior classification performance combining cochleogram and ViT, highlighting the potential of ViT for reliable respiratory sound classification. This study contributes to the ongoing efforts in developing automatic intelligent techniques with the aim to significantly augment the speed and effectiveness of respiratory disease detection, thereby addressing a critical need in the medical field.

Для цитирования: Mang Loredana Daria, González Martínez Francisco David, Martinez Muñoz Damian, García Galán Sebastián, Cortina Raquel. Classification of Adventitious Sounds Combining Cochleogram and Vision Transformers.. Sensors (Basel, Switzerland). 2024. DOI: 10.3390/s24020682.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.