MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.arthro.2012.12.003

Медицинская библиотека · Arthroscopy : the journal of arthroscopic & related surgery : official publication of the Arthroscopy Association of North America and the International Arthroscopy Association · 2013

Biomechanical comparison of open and arthroscopic Latarjet procedures.

Schulze-Borges Johanna, Agneskirchner Jens D, Bobrowitsch Evgenij, Patzer Thilo, Struck Melena, Smith Tomas, Wellmann Mathias

Сравнительное исследованиеСтатьяПеревод в очереди

Аннотация

PURPOSE: To biomechanically compare the effectiveness of the standard open and arthroscopic techniques of the Latarjet procedure to address a critical anterior glenoid defect in combination with a capsular insufficiency.

METHODS

Translation testing of 12 human cadaveric shoulder specimens was performed in a robot-assisted setup under 3 different conditions: (1) intact/vented shoulder joint, (2) combined anterior glenoid bone and capsular defect, and (3) open and arthroscopic Latarjet procedures. Testing was performed for each condition in 2 test positions: 60° of glenohumeral abduction with neutral rotation (ABD position) and 60° of abduction and external rotation (ABER position). Each position was tested with a passive humerus load of 30 N in the anterior, inferior, and anteroinferior directions. Translational movement of the humeral head was evaluated with and without the application of a 10-N load to the conjoint tendon (CJT).

RESULTS

In the ABD position, translations after the open Latarjet procedure significantly differed from the arthroscopic technique in the anterior and anteroinferior directions when testing was performed with loading of the CJTs (CJT loading). Without CJT loading, the open Latarjet technique showed significantly lower translations in the anterior, inferior (P = .004), and anteroinferior (P = .001) testing directions in the ABD position. In the ABER position, the arthroscopic procedure showed no significant difference compared with the standard open procedure.

CONCLUSIONS

We found a superior stabilization effect of the open Latarjet technique in the ABD position. The difference is ascribed to the anterior capsular repair, which was performed within the open technique and omitted during the arthroscopic procedure.

CLINICAL RELEVANCE: The reduction of translation in a pure abduction position of the arm is more effectively performed with a conventional open Latarjet technique that includes a capsular repair. In combined ABER position, there was no difference found between the open and arthroscopic Latarjet techniques.

Для цитирования: Schulze-Borges Johanna, Agneskirchner Jens D, Bobrowitsch Evgenij, Patzer Thilo, Struck Melena, Smith Tomas, Wellmann Mathias. Biomechanical comparison of open and arthroscopic Latarjet procedures.. Arthroscopy : the journal of arthroscopic & related surgery : official publication of the Arthroscopy Association of North America and the International Arthroscopy Association. 2013. DOI: 10.1016/j.arthro.2012.12.003.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.