Pharmacokinetics and pharmacodynamics of the proposed biosimilar denosumab GP2411 and reference denosumab in healthy males.
Аннотация
BACKGROUND
This Phase I study compared the pharmacokinetic (PK) and pharmacodynamic (PD) similarity of GP2411 proposed denosumab biosimilar to reference denosumab (a monoclonal antibody for specific pro-resorptive conditions).
RESEARCH DESIGN AND
METHODS
Healthy males (28-65 years, 50-90 kg) were randomized to a single sub-therapeutic subcutaneous injection of 35 mg GP2411, EU-Xgeva® or US-Xgeva®, and followed for 39 weeks. The primary endpoints were AUCinf, AUClast, and Cmax.
RESULTS
Four hundred ninety-two participants completed treatment. The 90% confidence intervals (CIs) (AUCinf, AUClast, and Cmax) and 95% CI of the geometric mean ratios of AUEC of % change from baseline in serum CTX were fully contained within the prespecified equivalence margins (0.80, 1.25), demonstrating similarity. The occurrence of treatment-emergent adverse events (TEAEs) with GP2411, EU-Xgeva® and US-Xgeva® was similar (72.9%, 76.0%, and 71.0% of participants, respectively). Most were Grade 1 or 2, <30% were treatment-related, and there was only one TEAE-related study discontinuation. Rates of positive anti-drug antibodies (ADAs) were similar (57.8%, 64.9%, and 69.1% of participants respectively), but immunogenicity was only borderline detectable and of very low magnitude. Ninety-nine percent of positive ADAs were transient.
CONCLUSION
GP2411 demonstrated similarity with EU-Xgeva® and US-Xgeva® in PK, PD, safety, and immunogenicity in this population.
CLINICAL TRIAL REGISTRATION: EudraCT 2019-001651-39.