MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1111/j.1444-0938.2010.00576.x

Медицинская библиотека · Clinical & experimental optometry · 2011

Comparative efficacies of contact lens disinfecting solutions against Pseudomonas aeruginosa.

Amiri Mohammad Aghazadeh, Mohammadinia Mohadeseh, Tabatabaee Mehdi, Askarizadeh Farshad, Behgozin Abbas

Сравнительное исследованиеСтатьяПеревод в очереди

Аннотация

PURPOSE: The aim of the present study was to evaluate the disinfection properties of multipurpose contact lens disinfection solutions, based on the International Organization for Standardization (ISO) 14729 guidelines.

METHODS

Three lots of each of six multi-purpose solutions were tested as follows: Renu MultiPlus, Solo Care Aqua, All-Clean Soft, Contact All-in one Advanced, Hippia, Ginza multi-purpose solution and 0.9% normal saline solution were inoculated with the standard strain of Pseudomonas aeruginosa (ATCC 9027). The surviving bacteria were quantified at specified times. An average logarithm reduction in bacterial numbers at the manufacturer's minimum recommended disinfection time was determined and compared with the criteria for stand-alone disinfection products for each multi-purpose disinfection solution against each bacterial strain.

RESULTS

Renu MultiPlus, Solo Care, All-Clean Soft and Contact All-in one Advanced were effective in achieving a four logarithmic units reduction in the bacterial count; however, Renu MultiPlus and Solo Care Aqua resulted in the greatest reduction in bacterial numbers. The other solutions were not effective against Pseudomonas aeruginosa after specified times.

CONCLUSIONS

Generally, Renu MultiPlus, Solo Care Aqua, All-Clean Soft and Contact All-in one Advanced meet the ISO 14729 guidelines for stand-alone contact lens solutions.

Для цитирования: Amiri Mohammad Aghazadeh, Mohammadinia Mohadeseh, Tabatabaee Mehdi, Askarizadeh Farshad, Behgozin Abbas. Comparative efficacies of contact lens disinfecting solutions against Pseudomonas aeruginosa.. Clinical & experimental optometry. 2011. DOI: 10.1111/j.1444-0938.2010.00576.x.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.