MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1002/nau.22460

Медицинская библиотека · Neurourology and urodynamics · 2013

Pad stress tests with increasing load for the diagnosis of stress urinary incontinence.

Rimstad Liv, Larsen Elsa Skjønhaug, Schiøtz Hjalmar A, Kulseng-Hanssen Sigurd

СтатьяПеревод в очереди

Аннотация

AIM: The aim of the study was to test the ability of pad stress tests with increasing load (supine, jumping on the floor, and jumping on a trampoline) to document stress incontinence in subjectively stress incontinent women.

METHODS

In this prospective study 147 subjectively stress and mixed incontinent women performed consecutively the three pad stress tests with a bladder volume of 300 ml. Nineteen women performed a second trampoline pad stress test to test repeatability of the test. Nine continent women performed a trampoline pad stress test in order to determine if subjectively continent women would leak during the test.

RESULTS

Seventy-two women (49%) leaked during the supine, 136 (93%) leaked during the jumping, and 146 (99%) leaked during the trampoline pad stress test. The differences between pad stress tests were significant with P < 0.005. Correlation between the two trampoline pad stress tests was high at 0.8. None of the nine continent women leaked during the trampoline pad stress test.

CONCLUSION

The supine pad stress test has low sensitivity and is therefore often falsely negative. The jumping pad stress test is a simple test to perform and is satisfactory for everyday use. Subjectively stress incontinent women who do not leak during the jumping pad stress test may perform a trampoline pad stress test to document stress incontinence. The trampoline pad stress test is also simple to perform and detected leakage in 91% of the women who did not leak during the jumping pad stress test.

Для цитирования: Rimstad Liv, Larsen Elsa Skjønhaug, Schiøtz Hjalmar A, Kulseng-Hanssen Sigurd. Pad stress tests with increasing load for the diagnosis of stress urinary incontinence.. Neurourology and urodynamics. 2013. DOI: 10.1002/nau.22460.