MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1093/jvimsj/aalag108

Медицинская библиотека · Journal of veterinary internal medicine · 2026

Analytical validation, reference interval determination, and diagnostic performance of plasma symmetric dimethylarginine in cattle.

De Campos Charly, Barroca Inês de Brito Neves, Baydoun Zahida, Chenal Théo, Gonçalves-Brandão Manon, Schelcher François, Trumel Catherine

СтатьяВалидационное исследованиеПеревод в очереди

Аннотация

BACKGROUND

The efficacy of serum urea and creatinine concentrations in the diagnosis of kidney disease in cattle is limited because of their low sensitivity and specificity. Serum symmetric dimethylarginine (SDMA) concentration is correlated with glomerular filtration rate and has been reported to be useful for the diagnosis of kidney disease in other species.

HYPOTHESIS/

OBJECTIVES

Test the hypothesis that SDMA may be an effective biomarker for diagnosing kidney disease in cattle. The objectives were to assess the analytical performance of SDMA measurement using a benchtop analyzer to establish an SDMA reference interval in cattle, and to evaluate the efficacy of plasma SDMA concentration for the diagnosis of kidney disease in cattle.

ANIMALS: A total of 199 healthy animals (53 male and 96 female beef cattle and 50 female dairy cows) and 27 azotemic cows with confirmed kidney disease.

METHODS

A partial analytical validation of SDMA measurement using bovine plasma was performed including assessments of short- and long-term imprecision, linearity, and stability. The reference interval was established following American Society for Veterinary Clinical Pathology (ASVCP) recommendations. Finally, the diagnostic efficacy of SDMA was assessed by determination of specificity, sensitivity, and the area under the receiver operating characteristic curve.

RESULTS

The SDMA measurements showed acceptable analytical performance. The reference interval was 60-160 μg/L. No significant differences were found according to sex, breed, or food supply. Using the upper limit of the reference interval (160 μg/L) as the cut-off, sensitivity and specificity were 0.85 and 0.98, respectively.

CONCLUSIONS AND CLINICAL

IMPORTANCE

An SDMA cut-off of 160 μg/L shows promise for diagnosing kidney disease in cattle, but requires confirmation in future studies.

Для цитирования: De Campos Charly, Barroca Inês de Brito Neves, Baydoun Zahida, Chenal Théo, Gonçalves-Brandão Manon, Schelcher François, Trumel Catherine. Analytical validation, reference interval determination, and diagnostic performance of plasma symmetric dimethylarginine in cattle.. Journal of veterinary internal medicine. 2026. DOI: 10.1093/jvimsj/aalag108.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.