MedElevator Войти в исследования
← Поиск публикаций

DOI 10.3390/s24196257

Медицинская библиотека · Sensors (Basel, Switzerland) · 2024

Manganese Sulfanyl Porphyrazine-MWCNT Nanohybrid Electrode Material as a Catalyst for H2O2 and Glucose Biosensors.

Falkowski Michal, Leda Amanda, Hassani Mina, Wicinski Michal, Mlynarczyk Dariusz T, Düzgüneş Nejat, Marszall Michal P, Milczarek Grzegorz, Piskorz Jaroslaw, Rębiś Tomasz

СтатьяПеревод в очереди

Аннотация

The demetallation reaction of sulfanyl magnesium(II) porphyrazine with N-ethylphthalimide substituents, followed by remetallation with manganese(II) salts, yields the corresponding manganese(III) derivative (Pz3) with high efficiency. This novel manganese(III) sulfanyl porphyrazine was characterized by HPLC and analyzed using UV-Vis, MS, and FT-IR spectroscopy. Electrochemical experiments of Pz3 conducted in dichloromethane revealed electrochemical activity of the new complex due to both manganese and N-ethylphthalimide substituents redox transitions. Subsequently, Pz3 was deposited on multiwalled carbon nanotubes (MWCNTs), and this hybrid material was then applied to glassy carbon electrodes (GC). The resulting hybrid electroactive electrode material, combining manganese(III) porphyrazine with MWCNTs, showed a significant decrease in overpotential of H2O2 oxidation compared to bare GC or GC electrodes modified with only carbon nanotubes (GC/MWCNTs). This improvement, attributed to the electrocatalytic performance of Mn3+, enabled linear response and sensitive detection of H2O2 at neutral pH. Furthermore, a glucose oxidase (GOx)-containing biosensing platform was developed by modifying the prepared GC/MWCNT/Pz3 electrode for the electrochemical detection of glucose. The bioelectrode incorporating the newly designed Pz3 exhibited good activity in the presence of glucose, confirming effective electronic communication between the Pz3, GOx and MWCNT surface. The linear range for glucose detection was 0.2-3.7 mM.

Для цитирования: Falkowski Michal, Leda Amanda, Hassani Mina, Wicinski Michal, Mlynarczyk Dariusz T, Düzgüneş Nejat, Marszall Michal P, Milczarek Grzegorz, Piskorz Jaroslaw, Rębiś Tomasz. Manganese Sulfanyl Porphyrazine-MWCNT Nanohybrid Electrode Material as a Catalyst for H2O2 and Glucose Biosensors.. Sensors (Basel, Switzerland). 2024. DOI: 10.3390/s24196257.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.