MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1002/jum.70219

Медицинская библиотека · Journal of ultrasound in medicine : official journal of the American Institute of Ultrasound in Medicine · 2026

Deresuscitation Informed by Ultrasound in Patients With Septic Shock Trial: A Pilot Randomized Controlled Study.

Innes Brendan, Allison Christopher, Seidler Nicholas, Shen Burton, Fried Andrew, Phillips Gary, Levinson Andrew, Abbasi Adeel

СтатьяРандомизированное исследованиеПеревод в очереди

Аннотация

OBJECTIVES

The venous excess ultrasound (VExUS) can be used at the point-of-care to identify venous overload and end-organ congestion in an effort to individually tailor resuscitation and deresuscitation in patients with septic shock.

METHODS

We conducted a pilot randomized controlled feasibility trial of VExUS-guided fluid management in adult patients with septic shock. Participants were randomized to VExUS-guided fluid management or usual care. Daily ultrasounds were performed on all participants; in the VExUS-guided study arm, the clinical care team was informed of the VExUS results and given a fluid management recommendation (the intervention).

RESULTS

We enrolled 19 participants; 12 (63%) were randomized to the VExUS arm. The intervention period fluid balance was -65 mL (interquartile range [IQR] -1733 to 2016) in the VExUS arm compared to 2608 mL (IQR -435 to 4460) in the usual care arm (p = .21). The secondary outcomes of acute kidney injury, respiratory failure, hospital, and 30-day mortality did not differ significantly between the 2 arms; although the rates were lower in the VExUS arm.

CONCLUSIONS

We demonstrate that VExUS-guided fluid management in patients with septic shock is feasible, was not associated with an increased risk of adverse events, and may reduce the volume of fluids administered.

Для цитирования: Innes Brendan, Allison Christopher, Seidler Nicholas, Shen Burton, Fried Andrew, Phillips Gary, Levinson Andrew, Abbasi Adeel. Deresuscitation Informed by Ultrasound in Patients With Septic Shock Trial: A Pilot Randomized Controlled Study.. Journal of ultrasound in medicine : official journal of the American Institute of Ultrasound in Medicine. 2026. DOI: 10.1002/jum.70219.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.