MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1002/jssc.201901191

Медицинская библиотека · Journal of separation science · 2020

Rapid and accurate determination of trace volatile sulfur compounds in human halitosis by an adaptable active sampling system coupling with gas chromatography.

Xu Yu, Yu Zhongning, Chen Xiaobin, Zhou Yi, Zhou Kang, Zhang Zhuomin, Li Gongke

СтатьяПеревод в очереди

Аннотация

Halitosis with the main components of trace volatile sulfur compounds widely affects the quality of life. In this study, an adaptable active sampling system with two sample-collection modes of direct injection and solid-phase microextraction was developed for the rapid and precise determination of trace volatile sulfur compounds in human halitosis coupled with gas chromatography-flame photometric detection. The active sampling system was well designed and produced for efficiently sampling and precisely determining trace volatile targets in halitosis under the optimized sampling and detection conditions. The analytical method established was successfully applied for the determination of trace targets in halitosis. The limits of detection of H2 S, CH3 SH, and CH3 SCH3 by direct injection were 0.0140-23.0 μg/L with good recoveries ranging from 82.2 to 118% and satisfactory relative standard deviations of 0.4-9.5% (n = 3), respectively. The limit of detections of CH3 SH and CH3 SCH3 by solid-phase microextraction were 2.03 and 0.186 × 10-3  μg/L with good recoveries ranging from 98.3 to 108% and relative standard deviations of 5.9-9.0% (n = 3). Trace volatile targets in positive real samples could be actually found and quantified by combination of direct injection and solid-phase microextraction. This method was reliable and efficient for the determination of trace volatile sulfur compounds in halitosis.

Для цитирования: Xu Yu, Yu Zhongning, Chen Xiaobin, Zhou Yi, Zhou Kang, Zhang Zhuomin, Li Gongke. Rapid and accurate determination of trace volatile sulfur compounds in human halitosis by an adaptable active sampling system coupling with gas chromatography.. Journal of separation science. 2020. DOI: 10.1002/jssc.201901191.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.