MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.chroma.2017.09.026

Медицинская библиотека · Journal of chromatography. A · 2017

Hollow porous molecularly imprinted polymer for highly selective clean-up followed by influential preconcentration of ultra-trace glibenclamide from bio-fluid.

Ostovan Abbas, Ghaedi Mehrorang, Arabi Maryam, Asfaram Arash

СтатьяПеревод в очереди

Аннотация

In the present work, hollow porous molecularly imprinted polymer (HPMIP) was prepared via adopting a sacrificial support approach using glibenclamide (GB) as template, methacrylic acid (MAA) as functional monomer, ethylene glycol dimethacrylate as cross-linker (EGDMA) and mesoporous MCM-48 nanospheres as support. Owing to a short thickness of the foresaid HPMIP, a suitable steric structure was readily available that lead to fast and effective mass transfer of target analyte to sorbent and consequently supply high binding capacity. After ultrasonic-assisted dispersive solid phase extraction of urine sample, the analyte of interest was quantitatively pre-concentrated and determined by high performance liquid chromatography-ultraviolet detection (HPLC-UV). Influence of factors affecting the extraction efficiency such as sonication time, sample pH, sorbent dosage, and volumes of eluent and washing agents as well as their significant interactions were simultaneously optimized by experimental design methodology. Under optimized conditions, present method has linear response over concentration range of 10.0-3000.0μgL-1 in human urine samples with a satisfactory detection limit close to 3.5μgL-1. The inter-day precisions of the current method (coefficient of variation) are lower than 5%, while recoveries are more than 89.5%.

Для цитирования: Ostovan Abbas, Ghaedi Mehrorang, Arabi Maryam, Asfaram Arash. Hollow porous molecularly imprinted polymer for highly selective clean-up followed by influential preconcentration of ultra-trace glibenclamide from bio-fluid.. Journal of chromatography. A. 2017. DOI: 10.1016/j.chroma.2017.09.026.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.