Accelerated acute severe antibody-mediated graft failure related to a Ross procedure 17 years earlier.
Аннотация
A 31-year-old male patient underwent a heart transplantation due to dilated cardiomyopathy. He experienced accelerated acute antibody-mediated rejection despite being negative for human leukocyte antigen antibodies (0% panel-reactive antibodies prior to surgery). Further assessment revealed a common antigen between a homograft implanted 17 years earlier during the Ross procedure and the heart donor. The homograft likely induced specific antibody formation. Interestingly, panel-reactive antibody levels measured 7 years prior to transplantation were 7%. Because of the long time span between the Ross procedure and heart transplantation, no circulating antibodies could be detected in 2015, but reactivation of memory cells might potentially have led to this fulminant rejection episode. For future cases, particular attention should be given to patients with homografts.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.