DOI 10.1097/prs.0000000000007528
Cost-Effectiveness of Treatments after Closed Extraarticular Distal Radius Fractures in Older Adults from the WRIST Clinical Trial.
Аннотация
BACKGROUND
This study performs an economic analysis of volar locking plate, external fixation, percutaneous pinning, or casting in elderly patients with closed distal radius fractures.
METHODS
This is a secondary analysis of the Wrist and Radius Injury Surgical Trial, a randomized, multicenter, international clinical trial with a parallel nonoperative casted group of patients older than 60 years with surgically indicated, extraarticular closed distal radius fractures. Thirty-Six-Item Short-Form Health Survey-converted utilities and total costs from Medicare were used to calculate quality-adjusted life-years and incremental cost-effectiveness ratio.
RESULTS
Casted patients were self-selected and older (p < 0.001) than the randomized surgical cohorts, but otherwise similar in sociodemographic characteristics. Quality-adjusted life-years for percutaneous pinning were highest at 9.17 and external fixation lowest at 8.81. Total costs expended were $16,354 for volar locking plates, $16,012 for external fixation, $11,329 for percutaneous pinning, and $6837 for casting. The incremental cost-effectiveness ratios for volar locking plates and external fixation were dominated by percutaneous pinning and casting. The ratio for percutaneous pinning compared to casting was $28,717. Probabilistic sensitivity analysis revealed a 10, 5, 53, and 32 percent chance of volar locking plate, external fixation, percutaneous pinning, and casting, respectively, being cost-effective at the willingness-to-pay threshold of $100,000 per quality-adjusted life-year.
CONCLUSIONS
Casting is the most cost-effective treatment modality in the elderly with closed extraarticular distal radius fractures and should be considered before surgery. In unstable closed fractures, percutaneous pinning, which is the most cost-effective surgical intervention, may be considered before volar locking plates or external fixation.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.