m+Medelevator.RU
← Поиск публикаций
The Journal of thoracic and cardiovascular surgery · 2018

Bentall procedure after previous aortic valve or complete root replacement: Usefulness of self-assembled aortic valve conduit.

СтатьяVideo-Audio MediaНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Urbanski Paul P, Lakew Fitsum, Dinstak Witold, Heinz Nicolas, Zacher Michael, Irimie Vadim, Reents Wilko

Аннотация

OBJECTIVES: The aim of this study was to evaluate surgical results of complete aortic root replacement using self-assembled valve composite graft in the setting of destroyed aortic annulus after previous valve replacement.

METHODS: Aortic root pathology being addressed by complete root replacement was combined with partial or complete absence of annular tissue in 112 consecutive patients. Eighty-eight had undergone a previous replacement of the aortic valve and 24 had undergone root replacement with a valved conduit. Altogether, 31 patients (27.7%) presented with acute endocarditis, which was the indication for surgery in 75% of patients with prior root replacement. In all patients, the root replacement or re-replacement was performed with a self-assembled valved conduit using mechanical (n = 74) or, in patients with an advanced age, biological (n = 38) valve prostheses.

RESULTS: In-hospital mortality was 11.6%, including a 30-day mortality of 6.3%. Resternotomy for bleeding was necessary in 5.4% of patients and about one-quarter did not need any blood transfusion. Estimated survival at 1, 5, and 10 years was 84.8% ± 3.4%, 75.7% ± 4.3%, and 57.1% ± 6.5%, respectively. Freedom from any valve-related events at 10 years was 86.2% ± 4.1%. During the follow-up time (mean, 63 ± 47 months), there was only 1 reoperation necessary 9 years after surgery (replacement of deteriorated biological valve prosthesis within the vascular tube leaving the conduit untouched).

CONCLUSIONS: A self-assembled composite graft allows safe proximal fixation of the conduit in patients with destroyed aortic annulus, resulting in sufficient proximal anastomosis and a very low incidence of aorta-related reoperations.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты