Nanophthalmos: quantitative analysis of anterior chamber angle configuration before and after cataract surgery.

Seki Masaaki, Fukuchi Takeo, Ueda Jun, Suda Kieko, Nakatsue Tomoko, Tanaka Yoko, Togano Tetsuya, Yamamoto Susumu, Hara Hiroaki, Abe Haruki

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

BACKGROUND/AIMS: To analyse quantitatively the anterior segment configuration in eyes with nanophthalmos before and after cataract surgery.

METHODS

This was a retrospective, non-comparative, interventional case series. Eleven eyes in eight patients with nanophthalmos who underwent phacoemulsification and intraocular lens implantation were identified from the department's surgical log, and their clinical records were retrospectively reviewed. Main outcome measures were as follows: visual acuity, intraocular pressure (IOP), axial length and the following ultrasound biomicroscopy parameters: angle opening distance at 500 μm anterior to the scleral spur (AOD500), trabecular-iris angle (TIA) and trabecular ciliary process distance.

RESULTS

The mean axial length of the eyes was 17.3 ± 1.7 mm. AOD500 and TIA increased after cataract surgery (p<0.005). Smaller axial length, AOD500 and TIA before cataract surgery were observed in eyes with preoperative IOP elevation than those without preoperative IOP elevation (p<0.05). Lower postoperative IOP was correlated with greater AOD500 and TIA before cataract surgery (p<0.05).

CONCLUSIONS

Cataract surgery deepened the anterior chamber and widened the anterior chamber angle in nanophthalmic eyes. Cataract surgery may have beneficial effects on IOP in eyes with nanophthalmos.

Для цитирования: Seki Masaaki, Fukuchi Takeo, Ueda Jun, Suda Kieko, Nakatsue Tomoko, Tanaka Yoko, Togano Tetsuya, Yamamoto Susumu, Hara Hiroaki, Abe Haruki. Nanophthalmos: quantitative analysis of anterior chamber angle configuration before and after cataract surgery.. The British journal of ophthalmology. 2012. DOI: 10.1136/bjophthalmol-2012-301496.