MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1111/echo.14471

Медицинская библиотека · Echocardiography (Mount Kisco, N.Y.) · 2019

Long-term performance of bicuspid and quadricuspid aortic valves: Similarities and differences.

Sharif Dawod, Azzam Elias, Sharif-Rasslan Amal

СтатьяПеревод в очереди

Аннотация

UNLABELLED: While bicuspid aortic valve (BAV) is a common congenital cardiac anomaly, quadricuspid aortic valve (QAV) is rare. The usual three-leaflet aortic valve is characterized by engineering advantages with superior long-term performance, and thus, degenerative changes and significant functional deterioration appear at advanced age.

AIM: Evaluation of long-term performance, similarities, and differences between QAV and BAV.

METHODS

Screening of 19 000 consecutive echocardiographic studies was performed.

RESULTS

BAV was reported in 131 subjects with a prevalence of 0.7%, while QAV was seen in 11 with a prevalence of 0.06%, P < .00001. Age of BAV patients was younger, 45 ± 20 years vs 62 ± 17 years in QAV, P < .05, with higher proportion of females in those with QAV, 40% vs 30%. Chamber diameters were similar in both groups. Higher atrial contraction-A-wave mitral peak velocities and longer E-wave deceleration times were found in subjects with QAV, P < .05 for both. Dilated ascending aorta was found in 25% of patients with BAV and in 18% of those with QAV, P = .2. Moderate and severe aortic valve stenosis were found in 21% of patients with BAV and in 27% of those with QAV, P = ns. More than moderate aortic regurgitation was found in 15.5% of BAV patients and in 9% of QAV, P = ns. Aortic valve infective endocarditis was found in 1.5% of BAV patients and in 9% of those with QAV.

CONCLUSIONS

BAV is a common congenital anomaly, while QAV is rare. Similar prevalence of significant valve disease and aortopathy was found in both anomalies, though at younger age in BAV patients.

Для цитирования: Sharif Dawod, Azzam Elias, Sharif-Rasslan Amal. Long-term performance of bicuspid and quadricuspid aortic valves: Similarities and differences.. Echocardiography (Mount Kisco, N.Y.). 2019. DOI: 10.1111/echo.14471.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.