MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1159/000505436

Медицинская библиотека · Medical principles and practice : international journal of the Kuwait University, Health Science Centre · 2019

Comparison of Panoramic Radiography and Cone-Beam Computed Tomography for the Detection of Tonsilloliths.

Ozdede Melih, Akay Gulsun, Karadag Ozge, Peker Ilkay

СтатьяПеревод в очереди

Аннотация

OBJECTIVE

A tonsillolith is a concretion of the tonsillar crypt. The aim of this retrospective study was to compare panoramic radiography (PR) and cone-beam computed tomography (CBCT) for the detection of tonsilloliths.

MATERIALS AND

METHODS

The CBCT images of 527 patients with maxillofacial volume were evaluated retrospectively. Of these, 175 patients (81 females, 94 males; mean age 51.05 years) had unilateral or bilateral tonsilloliths. In total, 151 of them (67 females, 84 males; mean age, 51.03 years) had PR images performed in the same period and were included in the study. The PR images were examined to ascertain whether known tonsilloliths (from CBCT images) could be detected. The location (unilateral; left or right and bilateral), size, and number of the tonsilloliths were examined on both CBCT and PR images. Descriptive analysis, Spearman's rho correlation coefficient, and χ2 tests were used for the statistical analysis.

RESULTS

The detection rate of tonsillolith was 33.2% on CBCT images. Only 51.4% of the tonsilloliths detected on CBCT were evaluated by PR; the correlation between CBCT and PR was found to be significant (Spearman's r = 0.399, p = 0.000). PR was not adequate to detect tonsilloliths 1 mm or smaller in size. All the calcifications larger than 5 mm were detected on PR images.

CONCLUSION

The results of this study showed that more than half of the tonsilloliths observed in CBCT were also detected in PR. Tonsilloliths larger than 2 mm were more likely to be detected on PR images.

Для цитирования: Ozdede Melih, Akay Gulsun, Karadag Ozge, Peker Ilkay. Comparison of Panoramic Radiography and Cone-Beam Computed Tomography for the Detection of Tonsilloliths.. Medical principles and practice : international journal of the Kuwait University, Health Science Centre. 2019. DOI: 10.1159/000505436.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.