MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1177/2325967121989252

Медицинская библиотека · Orthopaedic journal of sports medicine · 2021

Clinically Reliable Knee Flexion Angle Measured on Stress Radiography for Quantifying Posterior Instability in Posterior Cruciate Ligament Injury.

Ryu Dong Jin, Kwon Kyeu Baek, Jung Eui Yub, Lee Sung-Sahn, Kim Joo Hwan, Jang Min Chang, Wang Joon Ho

СтатьяПеревод в очереди

Аннотация

BACKGROUND

After posterior cruciate ligament injury, stress radiography is a common method of quantifying posterior instability, defined as the side-to-side difference in posterior tibial displacement (PTD) between the injured knee and contralateral noninjured knee. However, no study has evaluated the reliability of PTD according to knee flexion angle (KFA) measurements on stress radiographs.

PURPOSE: To evaluate the test-retest reliability of stress radiographic measurements of the KFA in the noninjured knee. In addition, we established a reliable range of KFAs to indicate posterior instability by comparing results with the instability measured at 90° KFA, which is considered the gold standard.

STUDY

DESIGN

Cohort study (diagnosis); Level of evidence, 3.

METHODS

We evaluated patients who had undergone bilateral stress radiographic examinations at least 5 times for ligament injuries between January 2013 and November 2019. All examinations were performed on a Telos device with a 150-N posterior load. A total of 120 knees and 644 stress radiographs were enrolled. We measured the KFA and PTD on stress radiographs and evaluated the reliability of repeated PTD measurement and the correlation between KFA and PTD.

RESULTS

The distribution of the actual noninjured knee KFA ranged from 56.9° to 106.7°. Among the 644 radiographs, 155 (24.1%) showed KFAs between 85° and 95°, and 287 (44.6%) showed KFAs between 80° and 85°. A significant correlation was found between KFA and PTD (P < .001), and the intrapatient intraclass correlation coefficient (ICC) was 0.788. A KFA range of 85° to 92° satisfied the criteria of high ICC (0.885) and nonsignificant correlation between KFA and PTD (P = .055) and thus was considered a reliable range of KFAs for quantifying posterior instability. We found no significant risk factors for measurement error, including age (P = .674), sex (P = .328), height (P = .957), weight (P = .248), or body mass index (P = .257).

CONCLUSION

We found high reproducibility of posterior displacement measurements on Telos stress radiography at a KFA of 85° to 92° in noninjured knees.

Для цитирования: Ryu Dong Jin, Kwon Kyeu Baek, Jung Eui Yub, Lee Sung-Sahn, Kim Joo Hwan, Jang Min Chang, Wang Joon Ho. Clinically Reliable Knee Flexion Angle Measured on Stress Radiography for Quantifying Posterior Instability in Posterior Cruciate Ligament Injury.. Orthopaedic journal of sports medicine. 2021. DOI: 10.1177/2325967121989252.