Percutaneous, ultrasound-guided single- and multisite cannulation for veno-venous extracorporeal membrane oxygenation in neonates.
Аннотация
AIMS: Extracorporeal membrane oxygenation (ECMO) is a widely used technique to support neonates with severe respiratory failure. Data on percutaneous, ultrasound-guided veno-venous (VV) ECMO cannulation in neonates is still scarce. Aim of this study was to describe our institutional experience with ultrasound-guided percutaneous, VV ECMO cannulation in neonates with severe respiratory failure.
METHODS
Neonates receiving ECMO support at our department between January 2017 and January 2021 were retrospectively identified. Patients receiving VV ECMO cannulation performed by the percutaneous Seldinger technique by single- or multisite cannulation were analyzed.
RESULTS
A total of 54 neonates received ECMO cannulation performed by the percutaneous Seldinger technique. In 39 patients (72%) a 13 French bicaval dual-lumen cannula was inserted and in 15 patients (28%) two single-lumen cannulae were used. Cannulae positioning using the multisite approach was in all cases as desired. The tip of the 13 French cannula was located in the IVC in 35/39 patients, in four patients position was too proximal but did not dislocate during the ECMO run. One (2%) preterm neonate (weight 1.75 kg) developed a cardiac tamponade which was successfully managed with drainage. Median duration of ECMO was 7 days (interquartile range: 5-16 days). Forty-four patients (82%) were successfully weaned from ECMO and in 31/44 (71%) the ECMO cannulae were removed with a delay of 0.9-7.2 days (median 2.8 days) after weaning without noticing complications.
CONCLUSIONS
A correct cannula placement using the ultrasound-guided percutaneous Seldinger technique, for both single- and multisite cannulation, seems feasible in most neonatal patients receiving VV ECMO.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.