MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.jor.2013.09.008

Медицинская библиотека · Journal of orthopaedics · 2013

Treatment of unstable distal third clavicular fracture with locked distal radius plate.

Abdeldayem Ashraf, Nafea Waleed, Eid Abdelsalam

СтатьяПеревод в очереди

Аннотация

BACKGROUND

The ideal surgical fixation for displaced distal clavicle fractures should not involve restrictions of the movements of nearby joints.

AIM OF THE WORK: To evaluate the results of internal fixation of unstable displaced distal third clavicle fractures using locked distal radius plates.

PATIENTS AND

METHODS

Fifteen patients with Type II distal clavicle fractures were treated with open reduction and internal fixation using locked distal radius plates.

RESULTS

Thirteen patients achieved full range of motion of the shoulder while two patients had minor limitations. The mean modified shoulder score was 18.3 at the final follow-up. None of the patients developed implant failure, loss of reduction, wound breakdown, or deep infection.

CONCLUSION

Good clinical results can be achieved with locked distal radius plate fixation in Type II fractures of the distal clavicle. With this technique, range of shoulder movement could be restored early without the needs for implant removal.

Для цитирования: Abdeldayem Ashraf, Nafea Waleed, Eid Abdelsalam. Treatment of unstable distal third clavicular fracture with locked distal radius plate.. Journal of orthopaedics. 2013. DOI: 10.1016/j.jor.2013.09.008.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.