The Israel Medical Association journal : IMAJ · 2024

Concomitant Cardiac Surgical Procedures in Patients Undergoing HeartMate 3 Left Ventricular Assist Device Implantation.

СтатьяНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Eisenberger Jonathan, Somer Shmuel, Nachum Eyal, Ram Eilon, Lavee Jacob, Sternik Leonid, Morgan Jeffrey

Аннотация

BACKGROUND: Long-term support with a HeartMate 3 (HM3) left ventricular assist device (LVAD) has improved outcomes of patients with end-stage heart failure. However, there is a paucity of data on the outcomes of patients who underwent concomitant cardiac surgical procedure (CCSP) during HM3-LVAD implantation.

OBJECTIVES: To assess our single-center experience with patients who underwent CCSP during the implantation of an HM3-LVAD.

METHODS: From December 2016 until April 2022, 131 adult patients underwent HM3-LVAD implantation. A total of 23 patients underwent CCSP during the HM3-LVAD implantation+CCSP, and 108 underwent only HM3-LVAD implantation (HM3-only).

RESULTS: The median age was 59 ± 11 years (range 54-67), 82% (n=108) were male, and 76% (n=100) were implanted as a bridge-to-transplant. The concomitant procedures performed during the implantation included 8 aortic valve repairs/replacements, 14 tricuspid valve repairs, 4 patent foramen ovales or atrial septal defect closures, and 3 other cardiac procedures. The mean cardiopulmonary bypass time was 113 ± 58 minutes for the HM3-only group and 155 ± 47 minutes for the HM3+CCSP group (P = 0.007). The mortality rates at 30 days, 6 months, and 12 months post-implantation were 2 (9%), 5 (22%), and 6 (26%) respectively for the HM3+CCSP group, and 7 (6%), 18 (17%), and 30 (28%) for the HM3-only group (P = 0.658, 0.554, and 1.000).

CONCLUSIONS: Our experience demonstrated no significant difference in the 30-day, 6-month, and 12-month mortality rates for patients who underwent a CCSP during HM3-LVAD implantation compared to patients who did not undergo CCSP during HM3-LVAD implantation.