[Immuno-hemolytic transfusion reactions. III. Report of 61 cases].

Le Pennec P Y, Tissier A M, Mannessier L, Agulles O, Babinet J, Bidet M L, Bombail-Girard D, Cabaud J J, Cartron J, Chiaroni J, Desaint C, Krause C, Lamy B, Meyer F, Mortelecque R, Nafissi S, Rasongles P, Schweitzer B, Rouger P

Клиническое исследованиеКонтролируемое клиническое исследованиеСтатьяМногоцентровое исследованиеПеревод в очереди

Аннотация

Blood transfusion is mainly bound to immunological and infectious risks. The immunological risk originates from an incompatibility between the blood of the donor and that of the recipient; this risk remains insufficiently assessed. A multicentre study has been carried out by the French Blood Transfusion Society and the National Institute for Blood Transfusion. Sixty-one accidents due to an erythrocyte incompatibility were found: 26 cases with ABO incompatibility, and 35 cases with alloantibodies of other blood group systems. For the former category of accidents, the most frequent cause was due to a failure in the realization of the bedside ABO check. For the latter, the main problem was the achievement and the interpretation of antibody screening. The long term follow-up shows no chronic after-effects of immunological accidents. For each accident, errors have been identified and analysed. It was proven that they all originate from health care establishments.

Для цитирования: Le Pennec P Y, Tissier A M, Mannessier L, Agulles O, Babinet J, Bidet M L, Bombail-Girard D, Cabaud J J, Cartron J, Chiaroni J, Desaint C, Krause C, Lamy B, Meyer F, Mortelecque R, Nafissi S, Rasongles P, Schweitzer B, Rouger P. [Immuno-hemolytic transfusion reactions. III. Report of 61 cases].. Transfusion clinique et biologique : journal de la Societe francaise de transfusion sanguine. 1996. DOI: 10.1016/s1246-7820(96)80034-6.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.