Dual-chamber leadless pacemaker implant via the RIJ after failed femoral vein implant in a 65-year-old patient with symptomatic bradycardia, with left IJ port and right-sided AV fistula.

Lawa Shivani, Aizad Ghania, Bingham Charles, Cortez Daniel

Клинический случайСтатьяПеревод в очереди

Аннотация

INTRODUCTION

Sinus node dysfunction (SND) is a disorder defined by abnormal initiation and conduction of electrical signals from the sinoatrial node. The preferred first-line treatment for a patient with symptomatic SND is a permanent pacemaker implant. We describe the implantation of an Aveir dual-chamber leadless pacemaker through the right internal jugular vein in a 65-year-old female patient with inaccessible femoral veins and a chemotherapy port in the left internal jugular vein.

METHODS

A retrospective review was performed at the University of California at Davis of the dual-chamber leadless pacemaker (Aveir DR) procedure.

RESULTS

A 65-year-old female with a history of chronic dialysis use and chemotherapy, with persistence of left internal jugular vein port, presented with symptomatic bradycardia. After a failed attempt at an outside institution, she presented for a dual-chamber leadless pacemaker implant at our institution. Via the right internal jugular vein, the Aveir VR was deployed with stable thresholds, impedance, and sensing into the ventricular septum, with a subsequent atrial device being deployed with stable thresholds, impedance, and sensing into the right atrial appendage. Follow-up at 8 days demonstrated a ventricular threshold of 0.75V at 0.2 ms, impedance of 440 Ohms, and sensing of 9.9 mV. Follow-up atrial threshold of 0.75V at 0.2 ms, impedance of 400 Ohms, and P wave sensing of 0.8 mV.

CONCLUSION

Placement of the Aveir dual chamber leadless pacemaker is safe in an adult patient without any complications.

Для цитирования: Lawa Shivani, Aizad Ghania, Bingham Charles, Cortez Daniel. Dual-chamber leadless pacemaker implant via the RIJ after failed femoral vein implant in a 65-year-old patient with symptomatic bradycardia, with left IJ port and right-sided AV fistula.. Indian pacing and electrophysiology journal. 2025. DOI: 10.1016/j.ipej.2025.09.009.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.