MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.bja.2025.08.065

Медицинская библиотека · British journal of anaesthesia · 2025

Ecarin-based coagulation monitoring of argatroban in patients with heparin-induced thrombocytopenia: a prospective observational study.

Schiferer Arno, Schlömmer Christine, Scheriau Georg, Boryshchuk Daniela, Meyer Elias L, Benque Sebastian, Holaubek Caroline, Wendel-Garcia Pedro, Steinlechner Barbara

СтатьяНаблюдательное исследованиеПеревод в очереди

Аннотация

BACKGROUND

The anticoagulant argatroban, a direct thrombin inhibitor, serves as an alternative to heparin in patients with heparin-induced thrombocytopenia (HIT). However, its dose titration using activated partial thromboplastin time (aPTT) has limitations. We aimed to investigate whether ecarin clotting time (ECA-CT) correlates better with plasma argatroban concentrations than aPTT.

METHODS

In this single-centre, observational study, 22 patients with HIT undergoing cardiac surgery and receiving argatroban anticoagulation were monitored over 5 days. The outcomes assessed were aPTT and ecarin clotting time (ECA-CT ClotPro®) values, plasma argatroban concentrations measured by a functional assay, and their correlations with each other.

RESULTS

Ecarin clotting time demonstrated a strong correlation with plasma argatroban concentrations (r=0.881, 95% confidence interval [CI] 0.790-0.934, P<0.0001), but aPTT was not correlated (r=0.12, 95% CI -0.182 to 0.412, P=0.843). The association between plasma argatroban concentration and aPTT was near-random above aPTT values >55 s, and was best described by a nonlinear approximation. Factor XII was the main independent driver of aPTT variability apart from argatroban concentration. Conversely, ecarin clotting time was independently affected by Factor II, X, and XI apart from argatroban.

CONCLUSIONS

This study presents ECA-CT as a reliable point-of-care test for monitoring argatroban concentration in patients with HIT. aPTT demonstrated a pronounced inability to track argatroban concentrations, especially when aPTT was >55 s. These findings highlight the need to reconsider optimal anticoagulation targets when using argatroban.

Для цитирования: Schiferer Arno, Schlömmer Christine, Scheriau Georg, Boryshchuk Daniela, Meyer Elias L, Benque Sebastian, Holaubek Caroline, Wendel-Garcia Pedro, Steinlechner Barbara. Ecarin-based coagulation monitoring of argatroban in patients with heparin-induced thrombocytopenia: a prospective observational study.. British journal of anaesthesia. 2025. DOI: 10.1016/j.bja.2025.08.065.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.