m+Medelevator.RU
← Поиск публикаций
Journal of biomaterials science. Polymer edition · 2026

Experimental and machine learning-based investigation of ZnO-incorporated polyurethane/polyethylene glycol nanocomposite films for potential antibacterial urinary catheter film applications.

СтатьяНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Jud Haleeful, Aijaz Haya, Wani Nisar Ahmad

Аннотация

Catheter-related urinary tract infections (CAUTIs) remain a critical healthcare-associated complication, motivating the development of antibacterial polymeric materials for catheter applications. In this study, zinc oxide (ZnO) nanoparticles prepared under two calcination conditions (designated as nominal <50 nm and nominal <100 nm size groups) were incorporated into polyurethane/polyethylene glycol (PU/PEG) films by solvent casting at loadings of 5, 10, 20, and 30 wt%. The materials were characterized using Fourier-transform infrared spectroscopy (FTIR), scanning electron microscopy (SEM), water contact-angle measurements, and disk-diffusion assays against Escherichia coli and Staphylococcus aureus. The antibacterial results demonstrated concentration-dependent inhibition, reaching maximum inhibition zones of 17 mm against E. coli and 16 mm against S. aureus at 30 wt% nominal <50 nm ZnO. To rigorously evaluate structure-property-function relationships and prevent model overfitting on a compact dataset, an exploratory Random Forest regression model was integrated using Leave-One-Out Cross-Validation (LOOCV). The cross-validated model showed good fit within the studied dataset. Quantitative feature importance ranking confirmed that ZnO concentration is the main governing factor of antibacterial efficacy (90.6%), followed by surface contact angle (8.3%), whereas nominal particle size category (0.4%) and bacterial species (0.6%) contributed minimally to overall variance. The results demonstrate the potential of cross-validated machine learning for exploratory feature screening in biomaterial design and indicate that ZnO-incorporated PU/PEG films warrant further investigation for potential urinary catheter applications. Direct coating adhesion, mechanical durability, cytocompatibility, release kinetics, biofilm inhibition, and performance on actual catheter substrates require future evaluation.

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты