DOI 10.24875/bmhim.21000225

Медицинская библиотека · Boletin medico del Hospital Infantil de Mexico · 2022

Perception of neonatology staff regarding the availability of equipment and supplies for the care of patients in need of nCPAP.

Osorno-Covarrubias Lorenzo, Villegas-Silva Raúl, Vega Alma Sánchez-de la, Vázquez-Cortés Francisco J, Muro-Flores Raúl H, Martínez-Sánchez Daniel

СтатьяПеревод в очереди

Аннотация

BACKGROUND

Respiratory distress syndrome (RDS) is Mexico's second leading cause of neonatal mortality. The 75% reduction in mortality due to RDS has been attributed to the use of nasal continuous positive airway pressure (nCPAP). A survey was conducted to determine the perception of the medical staff regarding the availability of nCPAP equipment and supplies in Mexican hospitals with neonatal intensive care units (NICUs).

METHODS

We sent a survey via e-mail to several neonatologists in each state of the country, requesting only one response per hospital. We performed statistical analysis with SPSS software.

RESULTS

We received 195 surveys from private (HPri) and public (HPub) hospitals with NICUs nationwide: 100% of HPri and 39% of HPub. More than 75% of the nursing and medical staff had received formal training in nCPAP in 11% of HPri and 5% of HPub. The perceived availability of CPAP equipment was 83.7% vs. 52.1%; nasal cannula supply, 75.5% vs. 36.3%; air/oxygen blender availability, 51.0% vs. 32.9%, in HPri and HPub, respectively. The observed differences were statistically significant. Significant differences were also found among healthcare institutions.

CONCLUSIONS

The availability of CPAP equipment and consumables between HPub and HPri is unbalanced and is lower in public institutions. Bubble CPAP is not included essential equipment in the national catalog of instruments and equipment for public hospitals, and its request is complicated. The training of CPAP staff and the availability of bubble CPAP and supplies in public hospitals should be improved.

Для цитирования: Osorno-Covarrubias Lorenzo, Villegas-Silva Raúl, Vega Alma Sánchez-de la, Vázquez-Cortés Francisco J, Muro-Flores Raúl H, Martínez-Sánchez Daniel. Perception of neonatology staff regarding the availability of equipment and supplies for the care of patients in need of nCPAP.. Boletin medico del Hospital Infantil de Mexico. 2022. DOI: 10.24875/bmhim.21000225.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.