Introduction

Percutaneous subclavian vein catheterization via infraclavicular approach is one of the most widely used cannulation techniques for inserting catheters into a central vein. The aim of this study was to evaluate influence of arm position during infraclavicular subclavian vein catheterization with landmark-based technique in coronary artery bypass graft (CABG) surgery.

Methods

Between September 2017 and June 2018, this prospective randomized clinical trial was performed in 320 patients. The patients were randomly assigned to the Neutral group (the arms kept by the side) or Abduction group (the arm was abducted to 90°). The success and complication rates were compared in the two groups. The data were analyzed using SPSS software.

Results

In the first attempt of subclavian vein cannulation, the success rate had no significant difference between the two groups (P = 0.185). In the second attempt of catheterization, the success rate in Abduction group (40.5%) was lower than Neutral group (81.2%). The overall success rate in two attempts were (84.4%) in the Abduction group and (96.2%) in the Neutral group. There was a significant difference between two groups in the second and overall success rates (P = 0.0001). In 34 (10.6%) patients, subclavian artery puncture occurred, 30 (18.8%) in the Abduction group and 4 (2.5%) in the Neutral group. There was a significant difference between two groups (P = 0.0001). Pneumothorax was occurred in 15 (9.4%) in the Abduction group and 3 (1.9%) in the Neutral group. There was also a significant difference between two groups (P = 0.004). The differences in other complications on two groups were statistically insignificant.

Conclusion

Compared with Abduction group, the Neutral group resulted in higher success rate and fewer subclavian artery puncture and pneumothorax. The incidences of other complications were similar on both groups.

Для цитирования: Tarbiat Masoud, Davoudi Maryam, Salimbahrami Sayed Ahmadreza. Influence of arm position during infraclavicular subclavian vein catheterization in coronary artery bypass graft surgery.. Journal of cardiovascular and thoracic research. 2018. DOI: 10.15171/jcvtr.2018.33.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.