MedElevator Войти в исследования
← Поиск публикаций

DOI 10.2214/ajr.184.5.01841470

Медицинская библиотека · AJR. American journal of roentgenology · 2005

16-MDCT in the detection of occult wrist fractures: a comparison with skeletal scintigraphy.

Groves Ashley M, Cheow Heok, Balan Kottekkattu, Courtney Helen, Bearcroft Philip, Dixon Adrian

СтатьяПеревод в очереди

Аннотация

OBJECTIVE

Our objective was to assess the potential use of MDCT in the detection of occult scaphoid fractures. Fifty-one patients with suspected radiographically occult scaphoid fractures at 10-14 days after trauma were investigated prospectively with skeletal scintigraphy and CT on the same day. Planar images of the wrist were taken 3 hr after IV injection of 400 MBq of (99m)Tc-methylene diphosphonate using a single-head gamma camera. CT was performed on a 16-MDCT machine using 0.75-mm detectors and reconstruction in 0.5-mm slices. Multiplanar reformatted images were then viewed in interactive cine mode. The examinations were reported independently, and discordant results were compared at follow-up. CT was positive for wrist fracture in 14 (27.4%) of 51 patients and skeletal scintigraphy in 23 (45.1%) of 51 patients. Even after retrospective review, there were seven discrepant cases (13.7%), all of which were positive for wrist fracture on scintigraphy but negative on CT. Four of these seven patients with discordant findings underwent further radiography at 6 weeks, which did not show fracture.

CONCLUSION

Although CT was preferred by most patients and was quicker, scintigraphy appears to detect bony abnormality more frequently. However, there appears to be an interesting group of patients (7/51) with normal initial radiography findings but positive scintigraphy findings who would normally be considered to have a fracture but for whom CT results were negative. In some of these patients, the results of follow-up radiography at 6 weeks were also negative, suggesting that this group of patients warrants further study.

Для цитирования: Groves Ashley M, Cheow Heok, Balan Kottekkattu, Courtney Helen, Bearcroft Philip, Dixon Adrian. 16-MDCT in the detection of occult wrist fractures: a comparison with skeletal scintigraphy.. AJR. American journal of roentgenology. 2005. DOI: 10.2214/ajr.184.5.01841470.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.