MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.jcmg.2021.02.022

Медицинская библиотека · JACC. Cardiovascular imaging · 2021

Hyperventilation/Breath-Hold Maneuver to Detect Myocardial Ischemia by Strain-Encoded CMR: Diagnostic Accuracy of a Needle-Free Stress Protocol.

Ochs Marco M, Kajzar Isabelle, Salatzki Janek, Ochs Andreas T, Riffel Johannes, Osman Nael, Katus Hugo A, Friedrich Matthias G

СтатьяПеревод в очереди

Аннотация

OBJECTIVES

The purpose of this study was to evaluate the diagnostic accuracy of a fast, needle-free test for myocardial ischemia using fast Strain-ENCoded (fSENC) cardiovascular MR (CMR) after a hyperventilation/breath-hold maneuver (HVBH).

BACKGROUND

Myocardial stress testing is one of the most frequent diagnostic tests performed. Recent data indicate that CMR first-pass perfusion outperforms other modalities. Its use, however, is limited by the need for both, a vasodilatory stress and the intravenous application of gadolinium. Both are associated with added cost, safety concerns, and patient inconvenience. The combination of 2 novel CMR approaches, fSENC, an ultrafast technique to visualize myocardial strain, and HVBH, a physiological vasodilator, may overcome these limitations.

METHODS

Patients referred for CMR stress testing underwent an extended protocol to evaluate 3 different tests: 1) adenosine-perfusion; 2) adenosine-strain; and 3) HVBH-strain. Diagnostic accuracy was assessed using quantitative coronary angiography as reference.

RESULTS

A total of 122 patients (age 66 ± 11years; 80% men) suspected of obstructive coronary artery disease were enrolled. All participants completed the protocol without significant adverse events. Adenosine-strain and HVBH-strain provided significantly better diagnostic accuracy than adenosine-perfusion, both on a patient level (adenosine-strain: sensitivity 82%, specificity 83%; HVBH-strain: sensitivity 81%, specificity 86% vs. adenosine-perfusion: sensitivity 67%, specificity 92%; p < 0.05) and territory level (adenosine-strain: sensitivity 67%, specificity 93%; HVBH-strain: sensitivity 63%, specificity 95% vs. adenosine-perfusion: sensitivity 49%, specificity 96%; p < 0.05). However, these differences in diagnostic accuracy disappear by excluding patients with history of coronary artery bypass graft or previous myocardial infarction. The response of longitudinal strain differs significantly between ischemic and nonischemic segments to adenosine (ΔLSischemic = 0.6 ± 5.4%, ΔLSnonischemic = -0.9 ± 2.7%; p < 0.05) and HVBH (ΔLSischemic = 1.3% ± 3.8%, ΔLSnonischemic = -0.3 ± 1.8%; p = 0.002). Test duration of HVBH-strain (t = 64 ± 2 s) was significantly shorter compared with adenosine-strain (t = 184 ± 59 s; p < 0.0001) and adenosine-perfusion (t = adenosine-perfusion: 172 ± 59 s; p < 0.0001).

CONCLUSIONS

HVBH-strain has a high diagnostic accuracy in detecting significant coronary artery stenosis. It is not only significantly faster than any other method but also neither requires contrast agents nor pharmacological stressors.

Для цитирования: Ochs Marco M, Kajzar Isabelle, Salatzki Janek, Ochs Andreas T, Riffel Johannes, Osman Nael, Katus Hugo A, Friedrich Matthias G. Hyperventilation/Breath-Hold Maneuver to Detect Myocardial Ischemia by Strain-Encoded CMR: Diagnostic Accuracy of a Needle-Free Stress Protocol.. JACC. Cardiovascular imaging. 2021. DOI: 10.1016/j.jcmg.2021.02.022.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.