MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1097/prs.0000000000013289

Медицинская библиотека · Plastic and reconstructive surgery · 2026

"Body composition as an indicator of the risk of complications after microvascular DIEP breast reconstruction".

Kerttula Suvi T, Majava Marja E, Kaartinen Ilkka S, Arponen Otso H, Vuorlaakso Miska A

СтатьяПеревод в очереди

Аннотация

BACKGROUND

The deep inferior epigastric perforator (DIEP) flap is a common breast reconstruction technique. As a microvascular procedure, it carries a risk of complications requiring careful patient selection. While high body mass index (BMI) is a recognized risk factor for complications, the role of muscle mass and more detailed body composition remains unclear. This study aimed to investigate the impact of low muscle mass and high BMI on complications in patients undergoing DIEP breast reconstruction.

METHODS

We retrospectively studied patients who underwent DIEP breast reconstruction at our tertiary center during the years 20182021. Preoperative CT scans were used to calculate skeletal muscle index (SMI). Patients were classified into four phenotype categories based on SMI (cut-off: 38.5 cm 2/m 2) and BMI (cut-off: 25 kg/m 2). Complication rates were evaluated and compared between phenotypes.

RESULTS

Altogether 204 patients were included, of which 29 (14.2%) met the criteria for sarcopenic overweight (SMI < 38.5 cm 2/m 2 & BMI > 25 kg/m 2). Complications occurred in 37 (18.1%) patients. Sarcopenic overweight associated with higher rates of early flap (p = 0.009) and overall (p = 0.034) complications compared to other phenotypes. In multivariable analysis, sarcopenic overweight was the only significant factor associated with overall complications (OR 8.66, 95% CI: 1.68-44.62, p = 0.010). Neither sarcopenia nor overweight alone were independent risk factors for complications.

CONCLUSIONS

In this study, sarcopenic overweight was associated with an eightfold increased risk of complications following DIEP breast reconstruction. Body composition, rather than mere BMI, should be considered when evaluating patients for breast reconstruction.

Для цитирования: Kerttula Suvi T, Majava Marja E, Kaartinen Ilkka S, Arponen Otso H, Vuorlaakso Miska A. "Body composition as an indicator of the risk of complications after microvascular DIEP breast reconstruction".. Plastic and reconstructive surgery. 2026. DOI: 10.1097/prs.0000000000013289.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.