MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1111/jce.13389

Медицинская библиотека · Journal of cardiovascular electrophysiology · 2017

Mechanical power sheath mediated recanalization and lead implantation in patients with venous occlusion: Technique and results.

Witte Olivier A, Adiyaman Ahmet, van Bemmel Marnix W, Smit Jaap Jan J, Ghani Abdul, Misier Anand R Ramdat, Elvan Arif, Delnoy Peter Paul H M

СтатьяПеревод в очереди

Аннотация

INTRODUCTION

Chronic venous occlusion hampers lead revisions and upgrades in patients with a cardiac implantable electronic devices (CIEDs). This can make cardiothoracic surgery, venoplasty, or contra-lateral implantation of leads with tunneling necessary. A technique using venous recanalization may be a preferred alternative. We assessed the efficacy and safety of this new technique.

METHODS AND

RESULTS

From 2009 to 2016, all consecutive patients planned for lead revision or upgrade with known chronic venous occlusion were studied. All patients underwent extraction of an existing malfunctional or functional CIED lead with the Cook Evolution mechanical power sheath. By using the lumen of the sheath, endovascular access to the heart was obtained for new leads. Forty-two patients (107 leads, 2.6 ± 1.1) were included. The indication for this procedure was replacement of malfunctional leads (n = 35, 83%) or device upgrade (n = 7, 17%). In total, 77 leads were extracted (30 leads stayed in situ) with a mean age at time of extraction of 8.4 years. Because of damage to bystander leads during extraction, two additional leads (one RA lead, one LV lead) were extracted. Clinical success was achieved in 41 patients (97%) and complete success in 39 patients (93%). There were two minor complications (two pocket hematomas, managed conservatively) and one major complication (tamponade, needing thoracotomy). Mean procedure time was 3.0 hours (median, 2.0; range, 1:28-5:35 hours) with a mean fluoroscopy time of 14.9 ± 12.5 minutes.

CONCLUSIONS

The technique of Evolution-mediated recanalization in case of lead revisions or upgrades is feasible with an acceptable safety profile and high efficacy.

Для цитирования: Witte Olivier A, Adiyaman Ahmet, van Bemmel Marnix W, Smit Jaap Jan J, Ghani Abdul, Misier Anand R Ramdat, Elvan Arif, Delnoy Peter Paul H M. Mechanical power sheath mediated recanalization and lead implantation in patients with venous occlusion: Technique and results.. Journal of cardiovascular electrophysiology. 2017. DOI: 10.1111/jce.13389.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.