MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.placenta.2024.11.004

Медицинская библиотека · Placenta · 2024

Development and validation of the placenta-QUS model for the detection of placenta-mediated diseases using quantitative ultrasound measurements: An Ex Vivo proof-of-concept study.

Deeba Farah, Hu Ricky, Lessoway Victoria, Terry Jefferson, Pugash Denise, Mayer Chantal, Hutcheon Jennifer, Rohling Robert

СтатьяВалидационное исследованиеПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

INTRODUCTION

Placenta-mediated diseases are associated with structural changes in the placenta. Quantitative Ultrasound (QUS) imaging measures the acoustic properties of the tissue, which are correlated to the underlying tissue structure. We aimed to develop and validate a diagnostic prediction model using QUS measurements for pre-eclampsia (PE) and small-for-gestational-age (SGA) fetuses/neonates.

METHODS

For this prospective case-control study, placentas were collected from a group of women who delivered via cesarean section at BC Women's Hospital, Vancouver, Canada. Ultrasound data were collected and processed to compute three QUS parameters, namely, attenuation coefficient estimate (ACE), integrated backscatter coefficient (IBC), and effective scatterer diameter (ESD) from the placentas. We developed a logistic regression model using QUS parameters as predictors. The primary outcome was the occurrence of SGA and PE.

RESULTS

The dataset consisted of 47 placentas, of which 25 placentas were complicated by SGA/PE. The final placenta-QUS model included quadratic and interaction terms of ACE, IBC, and ESD parameters. The placenta-QUS model was well-calibrated, with a calibration slope of 0.99 (0.57-1.05) and a calibration intercept of 0.003 (-0.02 - 0.22). The model predicted the SGA/PE complicated pregnancies with an apparent Area Under the Receive Operating Characteristic Curve (AUROC) of 0.89 (95 % CI: 0.78-0.98). The optimism-adjusted AUROC was 0.88 (95 % CI: 0.78-0.98).

DISCUSSION: A model for SGA and PE has been developed using QUS measures from the placenta ex vivo. The model showed promising performance in detecting SGA/PE. Future studies will be performed to assess the model performance using QUS measures in utero.

Для цитирования: Deeba Farah, Hu Ricky, Lessoway Victoria, Terry Jefferson, Pugash Denise, Mayer Chantal, Hutcheon Jennifer, Rohling Robert. Development and validation of the placenta-QUS model for the detection of placenta-mediated diseases using quantitative ultrasound measurements: An Ex Vivo proof-of-concept study.. Placenta. 2024. DOI: 10.1016/j.placenta.2024.11.004.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.