PURPOSE: In a retrospective study, we evaluated the complications in using the motility peg system (nonsleeved and sleeved) for hydroxyapatite orbital implants in an anophthalmic socket.

METHODS

Drilling for motility peg placement was performed in 265 patients with hydroxyapatite implantation: nonsleeved peg system (n = 191), sleeved peg system (n = 74). A statistical analysis was performed using the chi-square test.

RESULTS

Extrusion rates were significantly lower in the sleeved peg system (10.8%) compared to the nonsleeved peg system (27.2%) (P =.005). The other complications related to motility peg placement were granulation tissue overgrowth (4.2%), hydroxyapatite exposure around peg head (3.0%), and decentered peg (1.9%).

CONCLUSIONS

To minimize peg extrusion, the sleeved peg was better than the nonsleeved peg for use in primary motility peg placement.

Для цитирования: Lee Sang Yeul, Jang Jae Woo, Lew Helen, Kim Sung Joo, Kim Hye Young. Complications in motility PEG placement for hydroxyapatite orbital implant in anophthalmic socket.. Japanese journal of ophthalmology. 2002. DOI: 10.1016/s0021-5155(01)00459-2.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.