MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.jss.2026.02.032

Медицинская библиотека · The Journal of surgical research · 2026

Direct Oral Anticoagulants Are Associated With Less Bleeding Risk Than Warfarin in Patients Undergoing Liver Resections.

Sohail Abdullah, Powers Mary T, Suarez Tricia, Wittrock Kathryn, Jehan Faisal S, Kwon Yong K, Aziz Hassan

СтатьяСравнительное исследованиеПеревод в очереди

Аннотация

INTRODUCTION

The safety profile of direct oral anticoagulants (DOACs) compared to warfarin in patients undergoing liver resections remains an area of active research.

METHODS

We performed a retrospective analysis of the TriNetX database. Patients were categorized into two groups based on the anticoagulant they were on before surgery: DOACs or warfarin. The primary outcome measure was postoperative hemorrhage.

RESULTS

After propensity score matching, there were 1301 patients in each group. Patients taking preoperative DOACs were less likely to have intraoperative hemorrhage (0.76% versus 2.1%; P < 0.01). There was no difference in the need for postoperative angioembolization between the two groups (0.76% versus 0.75%; P = 1) or 30-d mortality (0.92% versus 1.7%; P = 0.06). A higher incidence of postoperative deep vein thrombosis/pulmonary embolism was observed in the warfarin group (16.4% versus 20.5%, P < 0.01).

CONCLUSIONS

This study suggests that DOACs demonstrate an improved safety profile compared to warfarin in patients undergoing liver resections. While further investigation is needed to uncover the underlying mechanism of these findings, the current trend in prescribing DOACs over warfarin is supported by the increase in positive outcomes, as seen in these results.

Для цитирования: Sohail Abdullah, Powers Mary T, Suarez Tricia, Wittrock Kathryn, Jehan Faisal S, Kwon Yong K, Aziz Hassan. Direct Oral Anticoagulants Are Associated With Less Bleeding Risk Than Warfarin in Patients Undergoing Liver Resections.. The Journal of surgical research. 2026. DOI: 10.1016/j.jss.2026.02.032.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.