m+Medelevator.RU
← Поиск публикаций
Endoscopy international open · 2026

Quantitative Assessment of Endoscope Tip Angulation Performance in New Endoscopes: A Cross-Sectional Quality Improvement Study.

СтатьяНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Kohli Saksham, Kotwal Vikram, Shah Mihir, Ahluwalia Daksh, Zhao Eric, Atluri Shalini, Gandhi Seema

Аннотация

Background Endoscope tip angulation is a key determinant of procedural maneuverability, yet routine quantitative assessment is not standardized, and data are limited on how quickly new endoscopes fall below manufacturer-specified performance benchmarks during routine use. The aim of this study was to evaluate tip angulation performance in new, apparently functional endoscopes after a period of clinical use and to characterize the prevalence and pattern of below-tolerance findings by scope type. Methods We performed a quality improvement project to evaluate the tip angulation of newly issued endoscopes within nine months of clinical use. In phase 1, endoscopes were systematically assessed by three trained physicians using a reference chart. In phase 2, a company representative independently evaluated endoscopes using a calibrated instrument. Results In all, 32 new endoscopes (18 colonoscopes and 14 gastroscopes) were evaluated. All scopes were used for approximately 9 months. The mean procedure count for colonoscopes was 185.6 (±12.5, range 162-201) and for gastroscopes was 150.6 (±12.0, range 133-166). Totally, 5 out of 18 colonoscopes (27.8%) fell below manufacturer tolerance thresholds for maximal tip deflection in at least one direction. All 14 gastroscopes met manufacturer tolerance thresholds in all four directions. Conclusions This cross-sectional study found that a notable proportion of new colonoscopes fell below manufacturer tolerance thresholds after approximately nine months of clinical use, despite being considered apparently functional. These findings highlight the need for periodic, objective assessment of tip angulation, even in endoscopes without apparent defects. Longitudinal studies are needed to establish deterioration trajectories and inform maintenance guidelines.

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты