Infections associated with locking reconstruction plates: a retrospective review.
Аннотация
PURPOSE: In this study, we examined the incidence of infection with the use of a locking reconstruction bone plate/system.
PATIENTS AND
METHODS
All patients, treated with a locking reconstruction bone plate/screw system for mandible fractures in the Oral and Maxillofacial Surgery service over a 28-month period at a level I trauma center, were evaluated through a retrospective chart review by independent examiners. The use of a locking reconstruction plate was determined by the attending staff involved in the patient's care. Patient population included single, bilateral, and comminuted fractures. Patient characteristics were noted and include dentate versus edentulous, smoking history, and history of previous infection.
RESULTS
Fifty-six locking bone plates were placed in 42 patients. Eight (19%) of the patients were infected before treatment. A persistent infection remained in 3 of these 8 patients (37.5%). Two patients (5.8%), with 3 fracture sites (6.4%) developed postoperative infection that required further intervention. All 5 of the patients who were infected after surgery were heavy smokers. History of preoperative infection and smoking appear to be significant factors in the etiology of postoperative infection. All postoperative infections resolved successfully with local measures and with no loss of fixation.
CONCLUSION
The use of locking reconstruction plates can facilitate the management of complicated fractures; however, it does not eliminate complications. Postoperative infections are related to numerous factors, including preoperative incidence of infection, smoking, and proper use of the plates.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.