DOI 10.1016/j.jcin.2017.07.045
Prosthetic Mitral Surgical Valve in Transcatheter Aortic Valve Replacement Recipients: A Multicenter Analysis.
Аннотация
OBJECTIVES
The aim of this study was to determine the prognosis and specific complications of patients with prosthetic mitral valves (PMVs) undergoing transcatheter aortic valve replacement (TAVR).
BACKGROUND
TAVR is performed relatively often in patients with PMVs, but specific risks are not well described.
METHODS
A multicenter analysis was conducted, including patients with severe symptomatic aortic stenosis who underwent TAVR at 10 centers. Patients' clinical characteristics and outcomes were evaluated according to the presence of a PMV.
RESULTS
The mean age of the study population (n = 2,414) was 81 ± 8 years, and 48.8% were men. A total of 91 patients (3.77%) had PMVs. They were more commonly women, younger, and had higher surgical risk. PMVs were implanted a median of 14 years before TAVR, and most patients had mechanical prostheses (73.6%). Eighty-six patients (94.5%) were on long-term vitamin K inhibitor therapy, and bridging antithrombotic therapy was administered in 59 (64.8%). TAVR device embolization occurred in 6.7% (vs. 3.3% in the non-PMV group; p = 0.127), in all instances when distance between the PMV and the aortic annulus was <7 mm. Mortality rates did not show a difference, but the rate of bleeding was higher in patients with PMV (24.2% vs. 16.1%; p = 0.041), even in those treated via the transfemoral approach (22.2% vs. 13.9%; p = 0.048). Indeed, bleeding complications, prior atrial fibrillation, chronic obstructive pulmonary disease, surgical risk, and New York Heart Association functional class were independent predictors of mortality.
CONCLUSIONS
TAVR presents similar mortality irrespective of the presence of a PMV. However, patients with PMVs had higher bleeding risk that was independently associated with higher mortality. Risk for valve embolization was relatively high, but it occurred only in patients with PMV-to-aortic annulus distances <7 mm.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.