MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s00392-025-02661-0

Медицинская библиотека · Clinical research in cardiology : official journal of the German Cardiac Society · 2025

Observer variabilities for the diagnosis of coronary artery disease using anatomical and functional testing: the impact of certification.

Korosoglou Grigorios, Abanador-Kamper Nadine, Tesche Christian, Renker Matthias, André Florian, Weichsel Loris, Hell Michaela, Bönner Florian, Cramer Mareike, Kelle Sebastian, Schulz-Menger Jeanette, Fehske Wolfgang, Rolf Andreas, Frey Norbert, Thiele Holger, Baldus Stephan

СтатьяСравнительное исследованиеПеревод в очереди

Аннотация

AIM: To compare the reproducibility in reporting of coronary computed tomography angiography (CCTA) or cardiovascular magnetic resonance imaging (CMR) by certified readers for CCTA and CMR by the German Society of Cardiology (DGK) versus that by non-certified readers.

METHODS

The study included 40 randomly selected CCTA and vasodilator stress CMR patient datasets. For CCTA, the degree of lumen narrowing, plaque composition, and high-risk plaque features were assessed. For CMR, wall motion and perfusion abnormalities and late gadolinium enhancement (LGE) were rated. All measures were conducted by segments and for individual patients. Intraclass correlation coefficients (ICC) were calculated to assess agreement between non-certified (n = 4) vs. DGK-certified readers (n = 4).

RESULTS

ICC for assessment of luminal narrowing, plaque composition, and high-risk features were, respectively, 0.65 (95% confidence intervals [CI] 0.59-0.69), 0.64 (95%CI 0.45-0.80), and 0.45 (95%CI 0.22-0.66) for non-certified versus 0.78 (95%CI 0.74-0.81), 0.88 (95%CI 0.79-0.93), and 0.89 (95%CI 0.81-0.95) for DGK-certified readers (p < 0.001 for all). ICC for the assessment of wall motion, perfusion, and LGE were, respectively, 0.41 (95%CI 0.35-0.48), 0.27 (95%CI 0.18-0.38), and 0.48 (95%CI 0.41-0.54) for non-certified versus 0.71 (95%CI 0.67-0.75), 0.71 (95%CI 0.67-0.75) and 0.67 (95%CI 0.62-0.71) for DGK-certified readers (p < 0.001 for all). The agreement was excellent among DGK-certified readers for obstructive CAD (≥ 70% lumen narrowing) assessed by CCTA and high for abnormal perfusion and for LGE by CMR in a per-patient analysis (0.88; 95%CI 0.79-0.94 and 0.84; 95%CI 0.71-0.92), respectively.

CONCLUSION

Substantially better CCTA and CMR reporting was observed for DGK-certified cardiologists, who achieved high agreement for diagnosing the presence or absence of obstructive CAD by CCTA and abnormal perfusion by CMR. Since important clinical decisions may be based on these readings, our data support quality-controlled education programs for advanced cardiac imaging.

Для цитирования: Korosoglou Grigorios, Abanador-Kamper Nadine, Tesche Christian, Renker Matthias, André Florian, Weichsel Loris, Hell Michaela, Bönner Florian, Cramer Mareike, Kelle Sebastian, Schulz-Menger Jeanette, Fehske Wolfgang, Rolf Andreas, Frey Norbert, Thiele Holger, Baldus Stephan. Observer variabilities for the diagnosis of coronary artery disease using anatomical and functional testing: the impact of certification.. Clinical research in cardiology : official journal of the German Cardiac Society. 2025. DOI: 10.1007/s00392-025-02661-0.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.