OBJECTIVES

This study sought to evaluate predictors of stroke during left ventricular assist device (LVAD) support from data available prior to implantation, and quantify stroke-related morbidity and mortality.

BACKGROUND

Stroke is a major complication after LVAD. Pre-implant factors that influence stroke are not well understood.

METHODS

We evaluated all patients in INTERMACS (Interagency Registry for Mechanically Assisted Circulatory Support) who were implanted with continuous flow LVADs from May 1, 2012, to March 31, 2015. Pre-operative risk factors for stroke and stroke incidence, morbidity, and mortality were analyzed.

RESULTS

During the study period, 7,112 patients underwent continuous flow LVAD placement. Median follow-up was 9.79 months (range 0.02 to 34.96 months). Of all patients, 752 (10.57%) had at least 1 stroke, with an incidence rate of 0.123 strokes per patient-year. A total of 447 (51.38%) strokes were ischemic and 423 (48.62%) were hemorrhagic. Patients with hemorrhagic stroke had worse survival than those with ischemic strokes (30-day survival: 45.3% vs. 80.7%; p < 0.001). Of patients with a first stroke, 13% had a second stroke. Pre-implant predictors of stroke were female sex (hazard ratio [HR]: 1.51; 95% confidence interval [CI]: 1.25 to 1.82; p < 0.001), pre-implant systolic blood pressure (HR: 1.01; 95% CI: 1.00 to 1.01; p = 0.002), heparin-induced thrombocytopenia (HR: 3.68; 95% CI: 1.60 to 8.47; p = 0.002), intra-aortic balloon pump (HR: 1.21; 95% CI: 1.01 to 1.46; p = 0.043), and primary cardiac diagnosis (ischemic/other/unknown) (p = 0.040).

CONCLUSIONS

Despite improvements in LVAD technology, stroke-related morbidity and mortality is substantial. Further investigation is necessary to decrease the risk of this devastating complication.

Для цитирования: Acharya Deepak, Loyaga-Rendon Renzo, Morgan Charity J, Sands Kara A, Pamboukian Salpy V, Rajapreyar Indranee, Holman William L, Kirklin James K, Tallaj José A. INTERMACS Analysis of Stroke During Support With Continuous-Flow Left Ventricular Assist Devices: Risk Factors and Outcomes.. JACC. Heart failure. 2017. DOI: 10.1016/j.jchf.2017.06.014.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.