MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s00345-026-06228-0

Медицинская библиотека · World journal of urology · 2026

Does pulse modulation technology improve endoscopic enucleation of the prostate? Real-world comparison of three contemporary laser platforms in 447 patients.

Castellani Daniele, Fong Khi Yung, Goumas Ioannis Kartalas, Tan Karl, Biligere Sarvajit, Yuen Steffi Kar-Kei, Zawadzki Marek, Bozzini Giorgio, Hota Thiago, Gauhar Vineet

Сравнительное исследованиеСтатьяМногоцентровое исследованиеНаблюдательное исследованиеПеревод в очереди

Аннотация

BACKGROUND

Anatomical Endoscopic enucleation of the prostate (AEEP) has emerged as a highly effective surgical treatment for benign prostatic enlargement, with multiple laser platforms now available. This study compares perioperative and early postoperative outcomes across three distinct laser systems.

METHODS

We analysed 447 patients who underwent AEEP across seven centres between March and August 2025. Patients were divided into three groups: Group 1 (n = 184) treated with Holmium: YAG laser employing Magneto technology, Group 2 (n = 64) with high-power Holmium: YAG laser, and Group 3 (n = 199) with pulsed Thulium: YAG laser. Perioperative parameters, complications, and three-month functional outcomes were assessed.

RESULTS

Group 3 demonstrated superior operative efficiency with shortest median total operation time (45 vs. 60 vs. 65 min, p < 0.001) and enucleation time (22 vs. 33 vs. 33 min, p < 0.001). No patients in Group 3 required electrocautery for haemostasis compared to 20.7% in Group 1 and 35.9% in Group 2 (p < 0.001). No patient required blood transfusion. No major complications occurred. Readmission for bleeding requiring manual clot evacuation occurred in 6.2% of Group 2 patients and 0.5% of Group 3 patients, with no cases in Group 1 (p < 0.001). Early and late urinary incontinence was significantly lower in Group 3 versus Groups 1 and 2. All platforms achieved substantial functional improvements at 3-month follow-up. No major complications.

CONCLUSIONS

While all three laser platforms achieved effective surgical outcomes with favourable safety profiles, the pulsed Thulium: YAG and Holmium: YAG lasers with magneto technology were associated with advantages in hemostasis and continence outcomes.

Для цитирования: Castellani Daniele, Fong Khi Yung, Goumas Ioannis Kartalas, Tan Karl, Biligere Sarvajit, Yuen Steffi Kar-Kei, Zawadzki Marek, Bozzini Giorgio, Hota Thiago, Gauhar Vineet. Does pulse modulation technology improve endoscopic enucleation of the prostate? Real-world comparison of three contemporary laser platforms in 447 patients.. World journal of urology. 2026. DOI: 10.1007/s00345-026-06228-0.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.