Endoscopic pressure study integrated system for the diagnosis of achalasia.

СтатьяНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Nishikawa Yohei, Inoue Haruhiro, Shimamura Yuto, Navarro Marc Julius, Kawamata Natsuki, Azuma Daisuke, Ushikubo Kei, Kimoto Yoshiaki, Yamamoto Kazuki, Fujiyoshi Yusuke, Okada Hiroki, Tanaka Ippei, Toshimori Akiko, Tanabe Mayo, Onimaru Manabu

Аннотация

OBJECTIVES: The endoscopic pressure study integrated system (EPSIS) is a novel diagnostic tool used to evaluate lower esophageal sphincter (LES) function. EPSIS allows the measurement of intragastric pressure (IGP) during gastric insufflation through esophagogastroduodenoscopy (EGD) and records its pressure waveform. This study aimed to assess the usefulness and applicability of EPSIS as an adjunct diagnostic modality for achalasia.

METHODS: This case-control study was conducted using a database of patients who underwent EGD, barium swallow (BS), high-resolution manometry (HRM), and EPSIS between January 2022 and December 2022. The achalasia (experimental) group (n = 35) consisted of patients with a definitive diagnosis of achalasia. The control group (n = 34) consisted of patients with no abnormalities in EGD, BS, or HRM and no abnormal acid reflux confirmed with 24-h pH-impedance monitoring. EPSIS findings were compared between the two groups and characterized by the waveform pattern (uphill or flat), maximum IGP (IGP-Max), pressure difference, and the gradient of the waveform.

RESULTS: All patients in the achalasia group showed an uphill pattern, in contrast to 21 patients (61.8%) in the control group. IGP-Max demonstrated the best diagnostic accuracy for achalasia, with a cut-off value of 15.8 mmHg (100% sensitivity, 58.8% specificity, and area under the curve [AUC] 0.78). The pressure gradient also demonstrated good diagnostic accuracy, with a cut-off value of 0.40 mmHg/s (80% sensitivity, 61.8% specificity, and AUC 0.76).

CONCLUSION: This study demonstrated that EPSIS can be applied as a diagnostic modality in patients with achalasia.