MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.scitotenv.2024.175478

Медицинская библиотека · The Science of the total environment · 2024

Centrifugated lateral flow assay strips based on dual-emission carbon dots modified with europium ions for ratiometric determination and on-site discrimination of tetracyclines in environment.

Hu Houwen, Xing Haoming, Zhang Yihao, Liu Xinru, Gao Sineng, Wang Linfan, Li Tingting, Zhang Ting, Chen Da

СтатьяПеревод в очереди

Аннотация

Due to the serious detrimental impact on human health, antibiotic pollution particularly tetracyclines residues has become a serious problem. Herein, a multiple response fluorescent probe consisted of dual-emission carbon dots and Eu3+ (D-CDs@Eu3+) is designed for the determination and discrimination of tetracyclines (TCs). Specifically, the carboxyl and amidogen group of dual-emission carbon dots (D-CDs) can coordinate with Eu3+ to form the D-CDs@Eu3+. Upon adding TCs, the fluorescence intensities of D-CDs at 405 nm and 495 nm are quenched due to inner filter effect (IFE) and the localization of fluorescence resonance energy transfer (L-FRET) between the D-CDs@Eu3+ and TC. Simultaneously, the D-CDs@Eu3+ may chelate with TCs to enhance the occurrence of antenna effect, while the characteristic peaks of Eu3+ at 590 nm and 615 nm are enhanced. On these bases, the TCs detection is achieved with low detection limits from 46.7 to 72.0 nM. Additionally, through the distinct efficiencies of L-FRET, the discrimination of TCs is achieved. Moreover, a novel centrifugated lateral flow assay strips (CLFASs) device is developed by integrating the D-CDs@Eu3+, lateral flow assay strips and smartphone using RGB variations for TCs detection, achieving remarkable recoveries (98.6-103.7 %) in real samples. Therefore, this CLFASs device provides a reliable approach for the TCs detection, demonstrating potential applications.

Для цитирования: Hu Houwen, Xing Haoming, Zhang Yihao, Liu Xinru, Gao Sineng, Wang Linfan, Li Tingting, Zhang Ting, Chen Da. Centrifugated lateral flow assay strips based on dual-emission carbon dots modified with europium ions for ratiometric determination and on-site discrimination of tetracyclines in environment.. The Science of the total environment. 2024. DOI: 10.1016/j.scitotenv.2024.175478.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.