The Journal of pediatrics · 2024
Cardiorespiratory Instability after Percutaneous Patent Ductus Arteriosus Closure: A Multicenter Cohort Study.
СтатьяМногоцентровое исследованиеНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Bischoff Adrianne R, Backes Carl H, Rivera Brian, Jasani Bonny, Patel Foram, Cheung Erica, Sathanandam Shyam, Philip Ranjit, McNamara Patrick J
Аннотация
OBJECTIVE: To evaluate postprocedural clinical characteristics of preterm infants undergoing transcatheter patent ductus arteriosus (PDA) closure, including oxygenation/ventilation failure and cardiovascular compromise.
STUDY DESIGN: Multicenter retrospective cohort study of preterm infants who were ≤2 kg at the time of percutaneous PDA closure between August 2018 and July 2021. Indices of cardiorespiratory stability were collected pre-closure, immediately post-closure, and subsequently averaged every 4 hours for the first 24 hours post-procedure. The primary outcome was incidence of post-transcatheter cardiorespiratory syndrome: composite of hemodynamic instability (defined by systemic hypotension, systemic hypertension, or use of new inotropes/vasopressors in the first 24 hours after catheterization) and at least one of the following: (i) ventilation failure or (ii) oxygenation failure.
RESULTS: A total of 197 patients were included with a median [IQR] age and weight at catheterization of 34 [25, 43] days and 1090 [900, 1367] grams, respectively. The primary composite outcome of post-transcatheter cardiorespiratory syndrome was reported in 46 (23.3%).
CONCLUSION: Post-transcatheter cardiorespiratory syndrome is characterized primarily by systemic hypertension and oxygenation failure, with a very low incidence of hypotension and need for inotropes.
STUDY DESIGN: Multicenter retrospective cohort study of preterm infants who were ≤2 kg at the time of percutaneous PDA closure between August 2018 and July 2021. Indices of cardiorespiratory stability were collected pre-closure, immediately post-closure, and subsequently averaged every 4 hours for the first 24 hours post-procedure. The primary outcome was incidence of post-transcatheter cardiorespiratory syndrome: composite of hemodynamic instability (defined by systemic hypotension, systemic hypertension, or use of new inotropes/vasopressors in the first 24 hours after catheterization) and at least one of the following: (i) ventilation failure or (ii) oxygenation failure.
RESULTS: A total of 197 patients were included with a median [IQR] age and weight at catheterization of 34 [25, 43] days and 1090 [900, 1367] grams, respectively. The primary composite outcome of post-transcatheter cardiorespiratory syndrome was reported in 46 (23.3%).
CONCLUSION: Post-transcatheter cardiorespiratory syndrome is characterized primarily by systemic hypertension and oxygenation failure, with a very low incidence of hypotension and need for inotropes.