m+Medelevator.RU
← Поиск публикаций
International journal of obstetric anesthesia · 2013

Outcomes of prospectively-collected consecutive cases of antenatal-suspected placenta accreta.

СтатьяНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Weiniger C F, Einav S, Deutsch L, Ginosar Y, Ezra Y, Eid L

Аннотация

BACKGROUND: Accurate diagnosis of placenta accreta is tentative before surgery. This study developed a predictive score for antenatal diagnosis of placenta accreta through mathematical modeling using clinical signs.

METHODS: Antenatal cases of suspected placenta accreta were collected prospectively in a single-site tertiary delivery center. Women with clinical signs of placenta accreta (placenta previa, number of previous cesarean deliveries and/or ultrasound suspicion of placenta accreta) were included. The diagnosis of accreta was confirmed surgically. The primary endpoint was the proportion of surgically-diagnosed placenta accreta among all suspected cases. Logistic regression modeling was performed to assess preoperative risk factors for placenta accreta. The risk score was tested on a receiver operator characteristic curve to identify subjects with placenta accreta and the optimum cut-point was chosen.

RESULTS: Over nine years, 92 suspected accreta cases were identified from 46623 deliveries (0.2%). The diagnosis was confirmed at surgery in 52/92 cases (56%) and there were no maternal deaths. Blood transfusion requirements were greater in patients with placenta accreta versus patients without placenta accreta (median 7 [range 0-25, interquartile range 3-10] versus 0 [0-6, 0-2] units of blood, P <0.0001). Area under the curve of the receiver operator characteristic curve was 0.846, with contribution from three variables (placenta previa, number of previous cesarean deliveries and ultrasound suspicion), each with a P value <0.05. From the ROC curve a cut-point with 100% sensitivity and specificity 25% (95% CI 12.69%-41.20%) was achieved, compared with 86.6% sensitivity (95% CI 74.21%-94.41%) and 60.0% specificity (95% CI 43.33%-75.14%) using ultrasound alone.

CONCLUSIONS: Combining diagnostic features associated with placenta accreta through mathematical modeling has better positive predictive value than ultrasound alone.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты