MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.cmpb.2024.108364

Медицинская библиотека · Computer methods and programs in biomedicine · 2024

Validation of classification system for isolated superior mesenteric artery dissections using image-based computational flow analysis.

Zhang Xuehuan, Chen Jiale, Qiu Chenyang, He Yangyan, Wang Bing, Zhang Hongkun, Wu Ziheng, Chen Duanduan

СтатьяВалидационное исследованиеПеревод в очереди

Аннотация

BACKGROUND AND

OBJECTIVE

The isolated superior mesenteric artery dissection (ISMAD) is a rare but potentially fatal vascular disorder. Classifications for ISMAD were previously proposed based on morphometric features. However, the classification systems were not standardized and verified yet. This study conducted computational flow analysis to validate the latest classification system of ISMAD and aid clinical decision-making based on hemodynamic parameters.

METHODS

62 patients with ISMAD were included and classified into different types according to false lumen structures (five types, Type I-V) and true lumen patency (two types, Type P and Type S) according to Qiu classification system. Computational fluid dynamics and three-dimensional structural analyses were conducted on the basis of computed tomography angiography datasets. Quantitative and qualitative functional analyses were performed via parameters of interest including volume flow of each minute, pressure drop, pressure gradient, the derivative parameters of wall shear stress such as time-averaged wall shear stress (TAWSS), oscillatory shear index (OSI), and the relative residence time (RRT). Statistical analyses were conducted among different ISMAD types.

RESULTS

TAWSS, OSI and RRT showed significant difference among different types when classified using false lumen structures. In detail, Type IV showed significantly higher TAWSS than other types (p = 0.007). OSI was obviously higher in Type II (p = 0.015). Type IV also presented the lowest RRT (p = 0.005). The pressure drop, pressure gradient, OSI and RRT showed higher value in Type S than that in Type P, demonstrating a statistical significance with p values of 0.017, 0.041, 0.001 and 0.012, respectively. While Type P had larger volume flow than Type S (p = 0.041).

CONCLUSIONS

The notable differences in hemodynamic features among different types demonstrated the feasibility of Qiu classification system. The evaluation based on hemodynamic simulation might also provide insights into risk identification and guide therapeutic decisions for ISMAD.

Для цитирования: Zhang Xuehuan, Chen Jiale, Qiu Chenyang, He Yangyan, Wang Bing, Zhang Hongkun, Wu Ziheng, Chen Duanduan. Validation of classification system for isolated superior mesenteric artery dissections using image-based computational flow analysis.. Computer methods and programs in biomedicine. 2024. DOI: 10.1016/j.cmpb.2024.108364.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.